摘要
洪屏抽水蓄能电站计算机监控系统采用南京南瑞集团公司自行开发、具有完全自主知识产权的SSJ-3000计算机监控系统。从使用者的角度出发,从设计、运行、维护等几个方面,对该监控系统与引进系统进行了对比,分析了监控系统国产化的优势,并指出了目前存在的问题,使其进一步成熟、完善。
The computer supervisory control system (CSCS) of SSJ- 3000 used in Hongping Pumped-storage Power Station is developed by Chinese NARI Group. From the point of view of user, the SSJ-3000 CSCS is compared with imported system from the aspects of system design, operation and maintenance. The advantages of domestic CSCS are analyzed, and the existing issues are also presented for further improvement.
出处
《水力发电》
北大核心
2016年第8期95-98,共4页
Water Power
关键词
计算机监控系统
国产化
设计
洪屏抽水蓄能电站
computer supervisory control system
localization
design
Hongping Pumped-storage Power Station