摘要
2015年国网湖北电科院对68台绝缘油色谱在线监测装置开展了测量误差计算,针对测量误差偏大现象,从检测原理、检测器温度、产品质量、安装方式以及现场运维管理5方面开展原因分析,并针对存在的问题提出了改进意见与建议。
In 2015, measurement error calculation of 68 on-line monitoring device of gases dissolved in transformer oil in Hubei Power Grid is carried out by Hubei Electric Power Research Institute . In view of the phenomenon of large measurement error, the reasons are analyzed from fiveaspects of the detection principle, the temperature of the detector, the quality of the product, theway of installation and the operation and maintenance management, and some suggestions for improvement are put forward in the end.
出处
《湖北电力》
2016年第2期28-32,共5页
Hubei Electric Power
关键词
绝缘油色谱在线监测装置
测量误差
原因分析
on-line monitoring device of gases dissolved in transformer oil
measurement error
cause analysis