摘要
由于机组在低负荷调峰情况下燃烧不稳定,严重影响机组的安全稳定运行,因此对某电厂一期300MW机组进行了低负荷稳燃实验,确定了机组不投油最低稳燃负荷,并对影响机组安全性的其他因素进行了分析并提出安全措施。
As the unit combust instability under the deep regulating load, seriously affect the safe and stable operation of the unit. We carried out a low-load stable combustion experiments on the first-stage 300MW unit of a power plant, determining the minimum of stable combustion load of unit without oil, and analyzed other factors which affect the safety of unit and proposed security measures.
出处
《黑龙江科技信息》
2016年第3期14-16,共3页
Heilongjiang Science and Technology Information
关键词
深度调峰
低负荷稳燃
安全性
Deep regulating load
Low-load stable combustion
Security