6自由度串联机器人D-H模型参数辨识及标定 被引量:72

Parameter Identification and Calibration of D-H Model for 6-DOF Serial Robots
原文传递
导出
摘要 为了提高串联机器人的末端绝对精度,本文首先采用轴线测量法识别机器人D-H参数模型,继而将D-H参数转化为最小完整连续运动学(CMMK)模型参数,并进行非线性优化,以解决D-H参数模型奇异和冗余带来的非线性优化不易收敛问题,最后,将优化后的CMMK模型参数转化为工业标准的D-H模型参数,再经过补偿后将其作为设计模型以获得更高精度的定位.通过在MOTOMAN-MH80机器人上进行试验,该方法能确实有效地识别机器人的杆件参数,未标定前机器人的位置误差只能达到2 mm左右,而标定后降至0.7 mm左右,精度提高了将近70%.本文方法通过轴线测量获取机器人模型参数初值,避免了对机器人进行理论建模的过程,与运动学回路法相比,具有较高的通用性;采用最小完整连续运动学模型进行标定,能有效解决D-H模型奇异性、非连续、不易收敛到正确值的问题. This paper intends to improve the absolute accuracy of the end-effector of serial robot. Firstly, the axis measurement method is used to identify the D-H(Denavit-Hartenberg) model parameters, and the D-H model parameters are transformed into the complete, minimal and model-continuous kinematic(CMMK) model parameters. Then, the parameters are optimized by the nonlinear method to solve the non-convergence problem of nonlinear optimization, which is caused by the singularity and redundancy of the D-H parameter model. Finally, the optimized CMMK model parameters are transformed into the industrial D-H model parameters, according to which the theoretical D-H parameter model is modified to accomplish high-accuracy calibration and position control. In experiments on MOTOMAN-MH80 robot, the robotic link parameters are effectively identified with the proposed method, and the positioning error decreases from 2 mm to 0.7 mm after calibration,ithe positioning accuracy is improved by about 70%. The proposed method can be used in more cases comparing with the kinematic loop method, because it obtains initial values of robot model parameters by axis measurement method and avoids the theoretical modeling process. Plus, problems of singularity, discontinuity and non-convergence of D-H model are solved effectively through the CMMK model based calibration.
出处 《机器人》 EI CSCD 北大核心 2016年第3期360-370,共11页 Robot
基金 国家自然科学基金(51575332) 机械系统与振动国家重点实验室课题(MSV2015010) 上海市教育委员会科研创新项目(2014Z10280034)
关键词 串联机器人 绝对精度 轴线测量法 最小完整连续运动学模型 serial robot absolute accuracy axis measurement method CMMK(complete minimal and model-continuous kinematic) model
  • 相关文献

参考文献3

二级参考文献18

  • 1LiuChangying YuZhijing CheRensheng YeDong HuangQingcheng YangDingning.BUNDLE ADJUSTMENTS CCD CAMERA CALIBRATION BASED ON COLLI NEARITY EQUATION[J].Chinese Journal of Mechanical Engineering,2004,17(4):494-497. 被引量:3
  • 2王品,廖启征,庄育锋,魏世民.一般7R串联机器人标定的仿真与实验[J].机器人,2006,28(5):483-487. 被引量:14
  • 3JUDD R P, KNASINSKI A B. A technique to calibrate industrial robots with experimental verification[J]. IEEE Trans. on Robotics & Automation, 1991, 6(1): 20-30. 被引量:1
  • 4HOLLREBACH J H, WAMPLER C W. The calibration index and taxonomy for robot kinematic calibration methods[J]. The International Journal of Robotics Research, 1996, 15: 573-591. 被引量:1
  • 5BENNETT D J, HOLLERBACH J M, GEIGER D. Autonomous robot calibration for hand-eye coordination[J]. The International Journal of Robotics Research, 1991, 10: 550-559. 被引量:1
  • 6STONE H, SANDERSON A. A prototype arm signature identification system[C]//IEEE International Conference on Robotics and Automation, March 30-April 3, 1987, Raleigh, North Carolina. Raleigh: IEEE, 1987: 175-182. 被引量:1
  • 7OTIERBACH R, GERDES R. Camera and robot hand/eye calibration using a three-dimensional calibration objects[C]//25th International Symposium on Industrial Robots, April 25-27, 1994, Hannover, Germany. Hannover: IEEE, 1994: 741-748. 被引量:1
  • 8ZIEGERT J, DATSERIS P. Basic considerations on robot calibration[C]// IEEE international conference on robotics and automation, April 25-29, 1988, Philadelphia, Pennsylvania. Philadelphia. IEEE, 1988: 932-938. 被引量:1
  • 9任永杰,邾继贵,杨学友,叶声华.利用激光跟踪仪对机器人进行标定的方法[J].机械工程学报,2007,43(9):195-200. 被引量:138
  • 10Bai Y,Zhuang H,Roth Z. S.Experiment Study of Puma Robot Calibration Using a Laser Tracking System[].IEEE international Workshop on Soft Computing in Industrial Applications.2003 被引量:1

共引文献80

同被引文献480

引证文献72

二级引证文献238

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部