选用单岛式地铁站,先通过实地测量获得数据,再结合地铁设计规范建立地铁站模型。利用Pyrosim模拟软件,模拟地铁站火灾过程,得出火灾过程中地铁站内各区域温度及烟气的变化趋势,为火灾情况下地铁人员的安全疏散提出建议。
Based on data from actual measurement andnormative data, a model of single island underground station wasestablished. The simulation software of pyrosim was used to simulateunderground station fire process to obtain the variationtendency of temperature and smoke of every area in the undergroundstation during the course of fire. Some proposals arepresented for safety personnel evacuation of the passengers whenthe the underground station is in the fire.