摘要 为建立检测抗菌金属材料的抗菌性能的方法。分别用ASTM E2149-13a法和ISO 22196——2011法对抗菌金属的抗菌性能和适用性进行比对研究,得出这两种方法都不太适合抗菌金属材料的抗菌性能检测。提出适宜于抗菌金属及其制品的抗菌性能检测方法:采用贴膜法,抗菌金属材料与菌液的作用时间为2 h。经实验证明:该方法重复性好、再现性佳,3种不同抗菌剂处理的金属材料抗菌率,其重复性分别为5.5%、5.6%和2.5%,同种抗菌剂处理的金属材料抗菌率的再现性为5.5%,说明该方法能应用于抗菌金属及相关材料抗菌性能检测。 The purpose of this paper is to design a detection method for antibacterial properties of antibacterial metallic materials. The antibacterial properties were detected and the applicability thereof was comparatively studied with both the ASTM E2149-13 a and ISO 22196——2011methods. The outcome suggests that the two methods were unsuitable for testing the antibacterial properties of antibacterial metallic materials. Then, a scientific and reasonable detection method was put forward. First, the antibacterial metallic materials and bacterial liquid were mixed with the sticking membrane method to react for 2 hours. It is proved from the test results that this method is stable and highly reproductive. The repeatability of the antibacterial rates of metallic materials treated by three different kinds of antibacterial agents is 5.5%, 5.6% and 2.5%respectively.The reproducibility of the same kind of antibacterial agent is 5.5%. It suggests that the proposed method can be used to detect the antibacterial properties of antibacterial metal and related materials.
出处 《中国测试》 CAS 北大核心 2016年第5期66-69,共4页 China Measurement & Test
基金 2015国家科技支撑计划项目(2015BAK45B00 2015BAK45B01)
关键词 抗菌性能 金属 检测方法 抗菌材料 antibacterial property metal detection method antibacterial materials
  • 相关文献

参考文献8

  • 1季君晖,史维明编著..抗菌材料[M].北京:化学工业出版社,2003:382.
  • 2刘秀英,吕斌,郭红莲,兰拓.我国抗菌产品性能检测标准体系现状[J].中国人造板,2009,16(8):27-30. 被引量:9
  • 3张晓,鲁建国,刘皓男.家电产品抗菌、除菌检测方法综述[C]∥2012年中国家用电器技术大会集,2012:621-623. 被引量:1
  • 4抗菌金属材料评价方法:SN/T 2399—2010[S].北京:中国质检出版社,2010. 被引量:1
  • 5Antimicrobial Products-Test for Antimicrobial Activity and Efficacy:JIS Z 2801—2000[S].2000. 被引量:1
  • 6Standard Test Method for Determining the Antimicrobial Activity of immobilized Antimicrobial Agents Under Dynamic Contact Conditions:ASTM E2149-13a[S].West Conshohocken:ASTM International,2010. 被引量:1
  • 7Plastics-Measurement of antibacterial activity on plastics surfaces:ISO 22196—2011(E)[S].2011. 被引量:1
  • 8解学魁,陈丽华,付亚书,刘绍强,刘绍威.抗菌制品的抑菌效果检测方法研究[J].中国公共卫生,2001,17(7):634-635. 被引量:10

二级参考文献7

共引文献17

同被引文献34

引证文献5

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部