目的研究浸渍法测量高密度聚乙烯瓶密度的不确定度来源。方法采用浸渍法对同批口服固体药用高密度聚乙烯瓶的密度重复进行了多次测量,分析了测量不确定度来源,并画出了来源因果图;建立了测量模型,对影响测量结果的各个不确定度分量分别进行了评定,并计算了合成标准不确定度和扩展不确定度。结果被测量的同批次口服固体药用高密度聚乙烯瓶密度为(0.950±0.002)g/cm3,其分散性在±0.002 g/cm3之间,符合规定。结论测量过程中对测得值影响较大的非重复性因素为浸渍液温度。
The aim of this study was to study the uncertainty sources for density measurements of HDPE bottles by impregnation method. Impregnation method was used to repeatedly measure the same batch of HDPE bottles for oral solid medicine, the measurement uncertainty sources were analyzed and the cause-effect diagram was depicted. A measurement model was established, each of the contributors to the uncertainty of the measurement results was evaluated respectively, and the combined standard uncertainty of the density measurement was calculated as well as the expanded uncertainty. The density of the HDPE bottles for oral solid medicine was measured to be ( 0.950± 0.002 ) g/cm3, with a dispersion between±0.002 g/cm3, which conformed the national standard. The main contributor to the type B uncertainty of the density measurement was the auxiliary liquid temperature.
出处
《包装工程》
CAS
CSCD
北大核心
2016年第1期15-18,88,共5页
Packaging Engineering
关键词
测量不确定度
浸渍法
口服固体药用高密度聚乙烯瓶
密度
measurement uncertainty
impregnation method
high-density polyethylene bottles for oral solid prepara-tion
density