摘要
由于能源结构原因,天然气点火在火力发电厂鲜有应用,导致天然气在火力发电中的应用经验缺乏。以土耳其阿特拉斯2×600 MW超临界锅炉机组为研究对象,结合火力发电企业特点,提出可以安全、可靠投入天然气系统的操作规程和规范;调试天然气系统,以满足锅炉点火、助燃、稳燃的要求。为同类型火电机组天然气管道设计、调试、运行提供借鉴。
Due to the energy structure of natural gas,natural gas ignition device is seldom used in thermal power plant.Taking the2x600 MW supercritical boiler in Turkey Atlas as an example,this paper discusses a series of issues including the operation regulation and standard of safe and reliable operation for natural gas system,and debugs the system to meet the requirements of boiler ignition,combustion-supporting and stabilized combustion,combining the characteristics of thermal power enterprise.
出处
《陕西电力》
2015年第12期89-94,共6页
Shanxi Electric Power
关键词
天然气系统
火力发电厂
超临界锅炉
燃煤机组
natural gas system
thermal power plant
supercritical boiler
coal-fired unit