利用负温度系数(NTC)热敏电阻和LTC2983模数转换芯片搭建了温度测量系统,基于此系统提出了一种温度残差补偿热敏电阻经验公式的标定方法。实验结果表明,多个热敏电阻的标定温度拟合残差绝对值小于0.10K,基本能够满足科研及工程领域对热敏电阻检测精度的要求。该系统在黑龙江漠河北极村段进行了安装和采集实验,通过温度数据获知了河流冰层变化的基本情况,证实了所提热敏电阻标定方法具有实际应用价值。
NTC thermistor and LTC2983 analog-to-digital chip were used to build a temperature measuring system,based on which,an optimization method of the thermistor empirical formula of temperature residual compensation was proposed.Experimental results show that the absolute value of the residual error of the calibrated temperature fitting of multiple thermistors is less than 0.10 K,which can basically meet the requirements of the detection accuracy of thermistor in scientific research and engineering fields.The system was installed and collected for experimentation in the Beijicun section of Mohe of the Amur River.Basic information of river ice changes was obtained through temperature data,confirming the significance of the proposed calibration method.
作者
程元国
邓霄
李灵傲
顾惠南
潘丽鹏
崔丽琴
张丽
CHENG Yuanguo;DENG Xiao;LI Ling’ao;GU Huinan;PAN Lipeng;CUI Liqin;ZHANG Li(College of Physics and Optoelectronics Engin.,Taiyuan University of Technol.,Taiyuan 030024,CHN;Key Lab.of Adv.Transducers and Intelligent Control System of the Ministry of Education and Shanxi Province,Taiyuan University of Technol.,Taiyuan 030024,CHN)
出处
《半导体光电》
CAS
北大核心
2019年第2期226-230,共5页
Semiconductor Optoelectronics
基金
国家自然科学基金项目(51641904
51809190
51205273)
山西省青年科技研究基金项目(2015021097)
国家留学基金项目(201508140062)
山西省研究生教育创新项目(2018SY020)
关键词
热敏电阻
温度
检测
标定
拟合
误差
thermistor
temperature
detection
calibration
fitting
error