期刊文献+

双氧水氧化测定废水中的总铬研究 被引量:1

Determination of Chromium in Wastewater Oxidized by Hydrogen Peroxide
下载PDF
导出
摘要 建立了碱性条件下双氧水氧化测定废水中总铬的方法。考察了前处理条件对测量体系的影响。在优化实验条件下,该方法检出限为0.003 mg/L;以2个样品为例,每个浓度进行6次平行测定,并对样品做消解前加标,铬的回收率为104%~114%之间,RSD≤5%。对两种不同的消解方法进行比对,结果证明:双氧水氧化法对测定废水中的总铬较好。 This paper established a method for determining chromium in wastewater,which is oxidized by hydrogen peroxide under alkaline environment. Working conditions of pretreatment have been investigated in detail. Under the optimal conditions,the detected limit is 0. 003 mg / L. The average recoveries are 104% ~ 114% and the relative standard deviation( RSD) is no more than 5% for two kinds of wastewater samples. As the results of comparison between two kinds of pretreatment shows,pretreatment using hydrogen peroxide is preferable to using potassium hypermanganate.
作者 陈秀梅
出处 《环境科学与管理》 CAS 2015年第11期127-129,共3页 Environmental Science and Management
基金 江苏省环境监测科研基金项目(1310)
关键词 前处理 双氧水氧化 总铬 废水 pretreatment oxidation with hydrogen peroxide chromium wastewater
  • 相关文献

参考文献6

二级参考文献6

共引文献70

同被引文献6

引证文献1

二级引证文献4

相关作者