期刊文献+

Experimental study on performance of contra-rotating axial flow fan 被引量:4

Experimental study on performance of contra-rotating axial flow fan
下载PDF
导出
摘要 Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow fan is experi- mentally investigated. The study is focused on the fan performance, the shaft power and the match between the motor and fan efficiency at different blade angles. The results show that the blade angle 43°/26° has the best aerodynamic perfor- mance. The first engine has a greater impact on the fan than the second one. The blade angle with the best aerodynamic performance does not necessarily correspond to the one with the best match between the motor and fan efficiency. The blade angle 43°/24° is the best choice for the operation of the fan in the present study.
作者 Shizhai Zhang
出处 《International Journal of Coal Science & Technology》 EI 2015年第3期232-236,共5页 国际煤炭科学技术学报(英文)
关键词 Contra-rotating axial flow fan Fan performance Shaft power Blade angle 对旋轴流风机 风机性能 空气动力学性能 叶片角度 实验 性能试验 最佳匹配 风扇