期刊文献+

电极面积对老龄垃圾渗滤液为底物的微生物燃料电池性能影响 被引量:9

Effects of electrode surface area on the performance of microbial fuel cells with the aging landfill leachate as substrate
下载PDF
导出
摘要 构建生物阴极型双室微生物燃料电池,处理老龄垃圾渗滤液。研究了阳极与阴极面积比值对微生物燃料电池产电能力和对老龄垃圾渗滤液处理效果的影响。结果表明,阳极与阴极面积比为1∶2、2∶2、2∶1的3组生物阴极型微生物燃料电池输出电压分别为408、452、396 m V,最大电功率密度分别为145.73、237.65、136.50 m W/m3,内阻分别为350、200、400Ω,COD的去除率分别为21.18%、20.20%、22.31%。3组微生物燃料电池运行30 d后,垃圾渗滤液中氨氮、硝酸盐氮、亚硝酸盐氮浓度均下降,其中,氨氮去除率分别为80.88%、73.61%和66.17%,其去除效果与产电性能相关。 Bio-cathode microbial fuel cells( MFCs) were built to treat the aging landfill leachate; the effect of electrode surface area on the aging landfill leachate treatment and electrical performance of MFCs was investigated. The results showthat for three sets of bio-cathode MFCs with the ratios of anode area to cathode area being 1∶ 2,2∶ 2 and 2∶ 1,the stable maximum output voltages are 408,452 and 396 m V,respectively,with the maximum electric power density of 145. 73,237. 65 and 136. 50 m W / m^3,the resistance of 350,200 and400 Ω,and COD removal rate of 21. 18%,20. 20% and 22. 31%,respectively. After running for 30 days,the concentration of ammonia,nitrate and nitrite nitrogen in landfill leachate is decreased; the ammonia removal rates for the three sets of MFCs are 80. 88%,73. 61% and 66. 17%,respectively,which is related to the electricity generation of MFCs.
出处 《燃料化学学报》 EI CAS CSCD 北大核心 2015年第8期1011-1017,共7页 Journal of Fuel Chemistry and Technology
基金 重庆市基础与前沿研究计划重点项目(CSTC 2013jj B20001)
关键词 微生物燃料电池 老龄垃圾渗滤液 电极面积 产电性能 microbial fuel cell aging landfill leachate electrode area electricity generation
  • 相关文献

参考文献3

二级参考文献35

共引文献47

同被引文献88

引证文献9

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部