期刊文献+

近零磁环境装置现状综述 被引量:13

Status Reviews for Nearly Zero Magnetic Field Environment Facility
下载PDF
导出
摘要 磁场极其微弱甚至接近零的特殊环境条件在科学研究和技术研发方面具有独特意义。通过被动屏蔽、主动补偿等手段,可在地磁场和各类干扰磁场的环境下实现这种近零磁场。世界各国已根据不同的应用需求建设了高水平近零磁环境装置,国内相关研究也已初步展开。结合近年来的最新成果,详细阐述了此类装置的建设方案与指标特性的现状。 The special environment in which the magnetic field is very weak and even nearly to zero hasunique and important applications in scientific and technology research. Through passive magnetic shielding, active compensation and other approaches, nearly zero magnetic fields can be realized in the ground condition with geomagnetic field and variable magnetic disturbances. Some high level nearly zero magnetic field environment facilities have been built in the world, and domestic researchers also have achieved some developments. Considering the recent developments in this field, the status reviews of these facilities including the construction design and performances are presented.
出处 《电工技术学报》 EI CSCD 北大核心 2015年第15期136-140,共5页 Transactions of China Electrotechnical Society
基金 国家自然科学基金青年科学基金(51407048) 哈尔滨工业大学科研创新基金(HIT.NSRIF 2013014)资助项目
关键词 近零磁场 微弱磁场 磁屏蔽 空间磁场 Nearly zero magnetic field, weak magnetic field, magnetic shielding, space magnetic field
  • 相关文献

参考文献16

  • 1Cohen D. A shielded facility h~r low-level magnetic measurements[J]. Journal of Applied Physics, 1967, 38(3): 1295-1296. 被引量:1
  • 2Cohen D. Large-volume conventional magnetic shields [J]. Revue de Physique Appliqu6e, 1970, 5(1): 53-58. 被引量:1
  • 3Mager A. Grossr~iumige magnetische abschirmungen [ J]. Journal of Magnetism and Magnetic Materials, 1976, 2 ( 1 ) : 245-255. 被引量:1
  • 4Lequain P, Berkhout J A, Schouten J. Design and construction at ESTEC of a magnetically shielded enclosure for VLF[ R]. ESA TN-125, 1977 : 1-32. 被引量:1
  • 5Kelh~i V. Construction amt performance of the Otaniemi magnetically shielded room[ C]. Biomagnetism, Berlin, 1981 : 33-50. 被引量:1
  • 6Erue S N, Hahlbohm H D, Scheer H, et al. The Berlin magnetically shielded room (BMSR) , Section B: Pertbrmances[C1. Biomagnetism, Berlin, 1981: 79-81. 被引量:1
  • 7Kajiwara G, Harakawa K, Ogata H, et al. High- pertbrmance magnetically shielded room[ Jl. IEEE Transactions on Magnetics, 1996, 32(4):2582-2585. 被引量:1
  • 8Moon S H, Oh B, Kim H T, et al. Two-channel high- te SQUID magnetometer for magnetocardiogramsIJ]. Journal of the Korean Physical Society, 1997, 31 (2) : 342 -346. 被引量:1
  • 9Bork J, Hahlbohm H D, Klein R, et al. The 8-layered nmgnetically shielded room of the PTB: l)esign and construction[ C]. Biomag 2000, Proceeding 12th International Conference on Biomagnetism, Espo o.Finland, 2000. 被引量:1
  • 10Thiel F, Schnabel A, Knappe-Gruneberg S, et al. Demagnetization of magnetically shielded rooms[Jl. Review of scientific instruments, 2007, 78(3) : 035106- 035106-13. 被引量:1