摘要 针对某火电厂超临界机组检修过程中发现的P91钢管硬度偏低的问题进行了化学成分分析、力学性能及硬度检测、金相检测等试验,结合现场检测中多例P91管硬度偏低的情况,总结发现表面脱碳造成P91钢管硬度检测值偏低的现象普遍存在。针对此现象提出了对检测中硬度偏低的P91钢管进行综合检验的建议,以避免误判。 Make an analysis of the causes for lower was found in a thermal power plant. Through the hardness in P91 steel pipes, which analysis of chemical components, mechanical property, hardness tesl and metallographic examination, combining some similar cases with the lower hardenss P91 steel pipes, the author summerized that the surface decarburization of the pipes existed widely. Therefore the author put torward that the comprehensive examination should be carried out to the steel pipes with lower hardness to prevent the misjudgment.
作者 董鹏
出处 《内蒙古电力技术》 2015年第3期74-76,共3页 Inner Mongolia Electric Power
关键词 P91钢管 硬度低 脱碳 铁素体 金相检测 P91 lower hardness decarburization ferrite metallographic examination
  • 相关文献

参考文献6

  • 1严泽生,刘永长,宁保群著..高CR铁素体耐热钢相变过程及强化[M].北京:科学出版社,2009:124.
  • 2电力行业电站金属材料标准化技术委员会.DL/T 438-2009火力发电厂金属技术监督规程[S].北京:中国电力出版社,2010. 被引量:1
  • 3全国钢标准化技术委员会.GB/T17394-1998金属里氏硬度试验方法[S].北京:中国标准出版社,2000. 被引量:1
  • 4美国材料与试验协会.ASTM335/335M-2010 Standard Specification for Seamless Ferritic Alloy-Steel Pipe For High-Temperature Service[EB/OL]. (2010) [2015-04-20]. http://wenku.baidu.com/view/f653341 efc4ffe473368ab3f.html. 被引量:1
  • 5王广生等编..金属热处理缺陷分析及案例 第2版[M].北京:机械工业出版社,2007:492.
  • 6上海市机械制造工艺研究所主编..金相分析技术[M].上海:上海科学技术文献出版社,1987:999.