摘要 根据JJF1059-1999测量不确定度评定与表示中规定的方法,利用测试数据,对湿度仪器的示值误差(修正值)的测量结果的不确定度进行了分析和评估。文中所遵循的技术路线、方法以及测量不确定度评定结果,可为省级气象计量部门的湿度项目建标考核、复查,提供技术参考,也可作为编写其它计量项目的建标技术报告时参考资料。 According to the requirements in the JJF1059-1999 evaluation and expression of uncertainty in the measurement and based on testing data, uncertainty in measurement for the indication error of humidity instrument has been analyzed and evaluated. The methods following the technical route and the evaluation results of measurement uncertainty can be built for standard examination and review on humidity project in provincial meteorological measurement. It also can be used as writing reference for other projects to build the report.
作者 邓卫勤
出处 《气象水文海洋仪器》 2015年第2期24-26,共3页 Meteorological,Hydrological and Marine Instruments
关键词 湿度仪器 示值误差 测量结果 不确定度评定 humidity instrument error value measurement result uncertainty evaluation
  • 相关文献

参考文献5

二级参考文献5

  • 1刘智敏,不确定度定理,1993年 被引量:1
  • 2北京市中计协通用技术研究所.DSP-2型标准数字式通风干湿表使用说明书[Z].,1990.. 被引量:1
  • 3天津气象仪器厂.DJM10型湿度检定箱使用说明书[Z].,1994.. 被引量:1
  • 4国家质量技术监督局计量司.测量不确定度评定与表达指南[Z].,2000—04.. 被引量:1
  • 5国家质量技术监督局.通用计量术语及定义[Z].,1999—03.. 被引量:1