期刊文献+

循环水泵冷却水管腐蚀失效分析

Failure Analysis on Cooling Water Pipe Corrosion of Circulating Water Pump
下载PDF
导出
摘要 循环水泵冷却水管发生严重腐蚀失效。通过ICP对管材进行成分分析,确定材料并无成分缺陷。再通过对腐蚀产物进行能谱分析和XRD扫描,发现Cl-可能是引起腐蚀失效的重要原因,而Cl-很有可能来自冷却水。因此建议改善冷却水质并改用耐Cl-腐蚀的材料制作冷却水管。 Circulating water pump cooling water pipe has serious corrosion failure. of steel composition by ICP, it determines that the composition of the material through the spectrum analysis and the XRD scan of corrosion products, it found important cause of corrosion failure; and CI- is likely to come from the cooling gives the suggestion that improving the cooling water quality and using the CI materials on cooling pipes. Through the anal has no defect. that Cl- may be ysls Then the water. Therefore, it corrosion-resistant
出处 《环境技术》 2015年第3期17-20,共4页 Environmental Technology
基金 广东省中国电器院风电装备腐蚀控制关键技术院士工作站(2013B090400023)项目资助 中国南方电网有限责任公司重点科技项目(K-GD2013-0501)项目资助
关键词 循环水泵冷却水管 腐蚀 失效 cooling water pipe of circulating pump corrosion failure