期刊文献+

非能动余热排出系统试验的失真度分析

Scaling Distortions Analysis of Passive Residual Heat Removal System Test
原文传递
导出
摘要 采用反应堆热工水力系统计算分析程序CATHARE分别对模块化小型堆ACP100原型反应堆和非能动余热排出系统(PRHRS)试验装置发生全厂断电事故(SBO)进行模拟,计算结果表明:PRHRS试验装置采用的模拟方法可以较好地反映ACP100反应堆原型的主要热工参数,失真度在可接受范围以内。 The Station Blackout Accidents (SBO) analysis is performed by CATHARE for passive reactor heat removal system (PRHRS) test facility and ACP100 respectively. The results show that the PRHRS test facility, which is designed according to the modified Ishii natural circulation scaling law, is capable of representing the thermal hydraulic parameters of prototype, and the scaling distortions are acceptable.
出处 《核动力工程》 EI CAS CSCD 北大核心 2015年第3期10-14,共5页 Nuclear Power Engineering
关键词 非能动余热排出系统试验装置 失真度分析 CATHARE PRHRS test facility, Scaling distortion analysis, CATHARE
  • 相关文献

参考文献5

  • 1ISHII M, KATAOKA I. Scaling laws for thermal- hydraulic system under single phase and two-phase natural circulation[J]. Nuclear Engineering and Design, 1984, 81:1-5. 被引量:1
  • 2Reyes J R, Hochreiter L. Scaling analysis for the OSU AP600 test facility (APEX) [J]. Nuclear Engineering and Design,1998, 86: 53-109. 被引量:1
  • 3Xin-Guo Yu, Hyun-Sik Park, Yeon-Sik Kim, et al. Systematic analysis of a station blackout scenario for APR1400 with test facility ATLAS and MARS code from scaling viewpoint[J]. Nuclear Engineering and Design, 2013, 259: 205-220. 被引量:1
  • 4杨世铭,陶文铨.传热学[M].北京:高等教育出版社,2007:112-124. 被引量:32
  • 5动力管道设计手册编辑组.动力管道设计手册[M].北京:机械工业出版社,2006. 被引量:1

共引文献31