期刊文献+

发电机组前置泵轴封改造分析

Analysis on Pre-pump Gland Sealing Reconstruction of Generation Units
下载PDF
导出
摘要 由于公司3号、4号机组前置泵机械密封冷却水质差,经常造成设备紧急停运。为了解决这个问题,把前置泵机械密封改为填料式密封,把冷却水由工业水改为凝结水和除盐水,通过改造使主设备处于良好的运行或备用状态,确保了主机安全稳定运行。 As the company # 3 # 4 units pre-cooling water pump mechanical seal poor, often caused by equipment outage emergency. To solve this problem, the pre-pump mechanical seal packing seal is replaced, the cooling water from industrial water changed in addition to condensation of water and saline. Through the transformation, the main device is in good running or standby mode, ensuring safe and stable operation of the host.
出处 《山东电力技术》 2010年第5期65-66,共2页 Shandong Electric Power
关键词 前置泵 机械密封 填料密封 轴封改造 pre-pump mechanical seal fill seal reconstruction of gland sealing system
  • 相关文献

参考文献5

  • 1吴民强主编..泵与风机节能技术[M].北京:水利电力出版社,1994:129.
  • 2郑体宽.热力发电厂[M].北京:中国电力出版社,1998.. 被引量:6
  • 3吴民强.泵与风机[M].北京:中国电力出版社,2000. 被引量:1
  • 4余三波.电力企业管理概论[M].北京:中国电力出版社,1992. 被引量:1
  • 5杨世铭,陶文铨.传热学[M].北京:高等教育出版社,2007:112-124. 被引量:32