目的分析层流洁净手术室空气质量监控不合格原因,改进管理措施,使层流洁净手术室的空气监测能够百分百达标。方法2013年11月前进行2次监测发现百级和千级各有2个手术间空气监测不合格,积极寻找原因并采取对策。于2013年12月—2014年2月采取措施后又进行4次空气监测。对改进前后手术室静态空气质量合格率进行比较。结果本院外科手术患者经院感监测I类手术切口感染率始终〈0.2%。改进后全部手术问空气质量监测均合格,大于改进前的监测合格率(85.7%),差异有统计学意义(P〈0.05)。结论对维持手术室洁净度的净化系统进行运行管理、清洁管理、无菌管理,对手术室空气采样人员进行培训,可提高层流洁净手术室空气质量监测合格率。
Objective To analyze the unqualified air reasons of laminar flow clean operation room when monitored, to strengthen the prevention and make sure static air of the laminar flow clean operating room air 100% qualified. Methods Each two of the 100 and 1 000 class laminar flow operation room had unqualified air before November 2013, and our department tried to find the reasons and countermeasures. From December 2013 to February 2014, we monitored air four times after carrying out countermeasures, and compared the qualified rate of operation room air with the air qualified rate before countermeasures used. Results The infection rate of I type operative incision were always below O. 2% in our hospital. After comprehensive improvement of operation room, the air qualified rate was beyond the rate of before improvement 85.7% with statistical significance ( P 〈 0. 05). Conclusions It can increase air qualified rate of laminar flow clean operation room by the operational management, cleaning management, aseptic management for maintaining operation room clean system and the training of air sampling personnel.
出处
《中华现代护理杂志》
2015年第13期1545-1547,共3页
Chinese Journal of Modern Nursing
关键词
空气质量监测
原因分析
预防
层流洁净手术室
Air quality monitoring
Reasons analysis
Prevention
Laminar flow clean operation room