摘要
研究了用TC500氧氮分析仪测定碳化铬中氮的分析条件。结果表明:采用称样量为0.10 g,镍囊包裹,分析功率5 000 W,比较器水平为3的条件下测定,可以得到满意的分析结果。对碳化铬进行分析,得到的相对标准偏差为1.42%,加标回收率在97.0%-101.2%之间。
The conditions for determination of nitrogen content in chromium carbide by TC500 nitrogen oxygen analyzer were studied. The results indicate that a satisfactory result can be obtained when the determination is carried out under following conditions: the sample with nickel capsule package 0.10 g, the analysis power 5000W ,the comparator level 3.The relative standard deviation is 1.42%, and the addition standard recovery is 97.0% ~ 101.2%.
出处
《当代化工》
CAS
2015年第5期1191-1192,共2页
Contemporary Chemical Industry
关键词
惰气熔融
热导法
碳化铬
氮
Inert gas fusion
Thermal conductivity method
Chromium carbide
Nitrogen