零飞仪在舰炮武器系统零飞试验安装过程中,因零飞仪摄像头光轴与炮管中心轴线不能完全重合,而导致标定时两中心轴线形成一夹角,由此引入安装误差。针对该问题,分析了该安装误差与标校距离、目标距离的关系,提出了误差修正方法,对零飞仪的安装使用及标校距离的选取具有指导意义。
During zero-fly equipment fixed in naval gun weapon system test,there is an angle which is the cause of no superposition between photograph axis and gun axis in the calibration,so a fixed error is impor-ted. The connection between the error and the distance of mark and target was analyzed and a method of correcting the error was presented. Some guidance value was provided for using zero-fly equipment and the choice of calibration distance.