摘要
目的:分析总结冠状动脉CT血管造影前瞻性心电门控及Carek V技术的临床应用价值。方法:回顾分析80例冠状动脉CT血管造影的影像资料,其中前瞻性心电门控及Carek V技术扫描组40例,回顾性扫描组40例,均采用ECG管电流自动调制技术。采用双盲法对图像质量进行评价,对所有冠状动脉节段(直径≥1 mm)进行图像质量评分;统计所有患者冠状动脉CT血管造影检查的辐射剂量。结果:1回顾性扫描组的个人总辐射剂量1.862-9.772 m Sv,平均辐射剂量为5.47 m Sv;前瞻性心电门控及Carek V技术扫描组的个人总辐射剂量0.862-2.996 m Sv,平均辐射剂量为1.27 m Sv。2前瞻性心电门控及Carek V技术扫描组40患者评价冠脉543段,能够满足诊断的图像(≤3分)比例为95.44%,评价为优的冠脉节段比例为89.57%。回顾性扫描组40患者评价冠脉576段,能够满足诊断的图像(≤3分)比例为97.82%,评价为优的冠脉节段比例为90.66%。结论:冠状动脉CT血管造影前瞻性心电门控及Carek V技术应用可提供优秀的、满足临床诊断的影像;冠状动脉CT血管造影前瞻性心电门控及Carek V技术应用是减少辐射剂量的有效方式之一。
Objective: To analyze and conclude the clinical value of prospective ECG-gated CT and carekV technology of coronary artery angiography. Methods: Eighty cases of coronary CT angiography image data were retrospectively analyzed. Forty cases were prospective ECG-gated and CarekV technology scanning group, the other 40 cases were retrospective scanning group. Both groups were conducted ECG automatic current modulation technique.With the double-blinded method, the image quality of all segmental coronary (diameter≥1 mm) and radiation dose in two groups were evaluated. Results: The individual total radiation dose in retrospective scan group was 1.862 mSv to 9.772 roSy, the average was 5.47 mSv. The individual total radiation dose in prospective ECG-gated and CarekV technology scanning group was 0.862 mSv to 2.996 mSv, the average was 1.27 mSv. There were 576 segments obtained in retrospective scanning group, in which 97.82% achieved diagnostic criteria (≤3 points), and there were 90.66% reached the excellent standard. In prospective ECG-gated and CarekV technology scanning group, there were 543 segments obtained, the rate of achieved diagnosis criteria was 95.44%, and 89.57% reached the excellent standard. Conclusion: The prospective ECG-gated CT and earekV technology in coronary CT angiography could provide excellent image which acheived clinical diagnostic standard and lower radiation dose.
出处
《大理学院学报(综合版)》
CAS
2015年第4期57-59,共3页
Journal of Dali University