期刊文献+

64排CT前瞻性心电门控冠状动脉成像降低辐射剂量的研究 被引量:9

Study of Radiation Dosage Reduction with Prospective ECG-gated 64-row CT Coronary Angiography
下载PDF
导出
摘要 目的通过比较64排螺旋CT前瞻性心电门控与回顾性心电门控冠状动脉成像的图像质量和辐射剂量,探讨前瞻性心电门控冠状动脉成像技术在降低辐射剂量中的作用。资料与方法 157例疑似冠状动脉疾病的患者随机分为两组,前瞻性心电门控组85例和回顾性心电门控组72例,两组心率均<65次/min,记录两组的成像质量和辐射剂量,并进行统计学分析。结果前瞻性心电门控组有效辐射剂量(4.42±1.52)m Sv明显低于回顾性心电门控组(14.84±3.98)m Sv(P<0.01),差异有统计学意义;前瞻性心电门控和回顾性心电门控两组冠状动脉成像质量评价差异无统计学意义(P>0.05),且前瞻性心电门控组图像优秀率略高于回顾性心电门控组。结论在较低且平稳的心率(≤65次/min)条件下,采用64排螺旋CT前瞻性心电门控技术即能有效降低辐射剂量,又能保证临床诊断所需的冠状动脉图像质量。 Objective To explore the role of prospective ECG-gated coronary angiography in reducing radiation dose by comparing image quality and radiation dose of prospective and retrospective ECG-gated 64-row CT coronary angiography. MaterialsandMethods 157 patients suspected coronary artery disease were divided in two groups. 85 patients were taken prospective ECG gating axial scan and 72 were taken retrospective ECG gating helical scan.The heart rate was ﹤65bmp.Coronary artery segments were assessed for imaging quality and radiation dose values were calculated. Results Effective radiation dose of prospective ECG gating group (4.42±1.52mSv) was significantly lower than that of retrospective ECG gating group (14.84±3.98mSv)(P〈0. 01). There was no significant difference in image quality between two groups(P﹥0.05),and image excellent rates of prospective ECG gating group was higher than that of retrospective ECG gating group. Conclusion Prospective ECG gating axial scan effectively reduces the radiation dose and receives similar image quality compared with retrospective ECG gating coronary angiography in patients with heart rates﹤65bpm.
出处 《中国CT和MRI杂志》 2015年第2期30-33,共4页 Chinese Journal of CT and MRI
关键词 体层摄影术 X线计算机 心电门控 辐射剂量 Tomography,X-ray Computed ECG-gating Radiation Dose
  • 相关文献

参考文献7

二级参考文献40

共引文献247

同被引文献80

  • 1肖喜刚,韩雪,王雪红,孙宏亮,王鸿振,牛洪涛.多层螺旋CT冠状动脉成像在冠心病中的临床应用[J].中华放射学杂志,2004,38(9):957-961. 被引量:66
  • 2黄美萍,刘其顺,刘辉,梁长虹,张绍斌.多层螺旋CT冠状动脉成像质量及对冠状动脉病变诊断准确性的评价[J].中华放射学杂志,2006,40(9):984-987. 被引量:83
  • 3吕滨,刘玉清,沈云.CT心脏成像的技术进展[J].中华放射学杂志,2007,41(10):1011-1013. 被引量:34
  • 4Mettler FA Jr, Thomadsen BR, Bhargavan M, et al. Medical radiation exposure in tile U. S. in 2006: preliminary results [J].Health Phys, 2008, 95 (5) : 502-507. 被引量:1
  • 5Brenner DJ, Hall EJ.Computed tomography:an increasing source of radiation exposure[J]. N Engl J Med, 2007,357 (22) :2277- 2284. 被引量:1
  • 6Naidich DP, Marshall CH, Gribbin C, et al. Low-dose CT of the lungs: preliminary observations[J]. Radiology, 1990, 175(3): 729-731. 被引量:1
  • 7No authors listed. The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction.Mul t idiscipl inary conference organized by tile Society of Pediatric Radiology augest 18- 19, 2001[J].Pediatr Radiol, 2002, 32(4): 217-313. 被引量:1
  • 8ttundt W, Rust FP, Stabler AM, et al. Dose reduction in multislice computed tomography[J].J Comput Assist Tomogr, 2005, 29 (1) : 140- 147. 被引量:1
  • 9Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2) :image quality of low-dose CT examinations in 80 patients[J]. Etlr Radiol, 2011, 21(3): 636- 643. 被引量:1
  • 10Bu Xtt, Ding XF, u RZ, et al. Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space[J].Clin Radiol,2011, 66 (11):1023- 1029. 被引量:1

引证文献9

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部