期刊文献+

湿热交换过滤器的功能及其并发症研究进展 被引量:1

The advance on the functions and complications of heat and moisture exchanging filters
原文传递
导出
摘要 背景 湿热交换过滤器是一类用于代替上呼吸道和鼻功能的人工装置,具有一定程度的保温、保湿和滤过功能.目的 概述湿热交换过滤器及其并发症,为临床医师的合理选择和使用提供参考.内容 通过总结大量的临床和实验室研究文献,客观地讲述呼吸过滤器的三大功能及其影响因素,同时也详细地介绍了可能发生的并发症.趋向 随着临床和实验室研究的深入,湿热交换过滤器会得到进一步的改进和完善. Background Heat and moisture exchanging filter is a kind of artificial device used to replace the upper respiratory tract and the nose function,with a certain degree of heat preservation,moisture and filtration function.Objective To summarize the heat and moisture exchanging filters and their complications for clinicians to use the devices appropriately.Content Through summarizing a large number of clinical and laboratory research literature,we objectively described three major functions of the heat and moisture filter and its influencing factors,and also introduces in detail the possibility of complications.Trend With the deepening of the clinical and laboratory research,heat an moisture exchangeing filter will be further improved and perfected.
作者 史天伍 张野
出处 《国际麻醉学与复苏杂志》 CAS 2015年第4期343-346,共4页 International Journal of Anesthesiology and Resuscitation
关键词 湿热交换过滤器 功能 并发症 Heat and moisture exchanging filters Function Complication
  • 相关文献

参考文献28

  • 1de Castro J Jr, Bolfi F, de Carvalho LR,et ai. The temperatureand humidity in a low -flow anesthesia workstation with and withouta heat and moisture exchanger [j]. Anesth Analg, 2011, 113(3):534-538. 被引量:1
  • 2Williams R, Rankin N, Smith T, et al. Relationship between thehumidity and temperature of inspired gas and the function of theairway mucosa[J]. Crit Care Med, 1996, 24(11): 1920-1929. 被引量:1
  • 3Wilkes AR. Heat and moisture exchangers and breathing systemfilters: their use in anaesthesia and intensive care. Part I -history,principles and efficiency [j]. Anaesthesia, 2011, 66( 1 ): 31 -39. 被引量:1
  • 4Lucato JJ, Adams AB, Souza R, et al. Evaluating humidity recoveryefficiency of currently available heat and moisture exchangers : arespiratory system model study [j]. Clinics (Sao Paulo), 2009,64(6): 585-590. 被引量:1
  • 5Merol JC , Charpiot A , Langagne T, et al. Randomized controlledtrial oil postoperative pulmonary humidification after totallaryngectomy: external humidifier versus heat and moistureexchanger[j]. Laryngoscope, 2012, 122(2): 275-281. 被引量:1
  • 6Lassen HC. A preliminary report on the 1952 epidemic of poliomyelitisin Copenhagen with special reference to the treatment of acuterespiratory insufficiency[j]. Lancet, 1953, 1(6749): 37-41. 被引量:1
  • 7Kleemann PP. Humidity of anaesthetic gases with respect to lowflow anaesthesia [J]. Anaesth Intensive Care, 1994,22(4): 396 -408. 被引量:1
  • 8Bengtson JP, Bengtson A, Sonander H, et al. Humidity of the Bainand circle systems reassessed[j]. Anesth Analg, 1989, 69(1): 83-86. 被引量:1
  • 9Hedley RM , Allt -Graham J. Heat and moisture exchangers andbreathing filters[j]. Br J Anaesth, 1994, 73(2): 227-236. 被引量:1
  • 10Chiumello D,Pelosi P, Park G, et al. In vitro and in vivo evaluationof a new active heat moisture exchanger [j]. Crit Care, 2004 , 8(5): R281-R288. 被引量:1

同被引文献10

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部