期刊文献+

128层多排螺旋CT前门控与非门控技术在小儿先天性心脏病中的应用对比 被引量:5

Comparison of prospective gating with non-gating technology of 128 multiple detector computed tomography in pediatric patients with congenital heart disease
下载PDF
导出
摘要 目的探讨128层多排螺旋CT(MDCT)前门控技术在小儿先天性心脏病检查的应用价值。方法分别采用前瞻性心电门控技术与螺旋非门控技术对2组各15例年龄、体质量相近的先天性心脏病患儿行128层MDCT心脏扫描。计算并比较2组的有效辐射剂量(ED)。对2组扫描显示不同解剖结构的图像质量进行主观评价并比较。结果门控组ED低于非门控组(P<0.05)。室间隔、房间隔、升主动脉、肺动脉主干的图像质量门控组高于非门控组(P<0.05);主动脉弓降部与两侧肺动脉干图像质量2组差异无统计学意义。结论对小儿先天性心脏病患者,应用前门控技术行128层MDCT心脏扫描可减低辐射剂量并提高图像质量。 Objective To explore the value of prospective gating technology of 128 multiple detector computed tomography(MDCT) in evaluating pediatric patients with congenital heart disease.Methods We performed 128 MDCT heart scan on two groups,each of which consisted of age and weight matched pediatric patients with congenital heart disease,prospective gating technology and non-gating technology being used respectively.Effective dose(ED) of radiation for each group was calculated and compared.Image quality of different anatomy structure in each group was rated subjectively and compared.Results Effective dose(ED) of gating group was lower than that of non-gating group(P〈0.05).Image quality of interventricular septum,interatrial septum,ascending aorta and main pulmonary artery was higher in gating group(P〈0.05),while the image quality of descending aortic arch and bilateral pulmonary trunk in the two groups had no statistically significant difference.Conclusion For pediatric patients with congenital heart disease,prospective gated 128 MDCT is capable of reducing radiation dose and promoting image quality.
出处 《实用医学影像杂志》 2015年第1期30-33,共4页 Journal of Practical Medical Imaging
关键词 体层摄影技术 X线计算机 心脏病 辐射剂量 Tomography X-ray computed Heart diseases Radiation dosage
  • 相关文献

参考文献10

二级参考文献49

  • 1黄美萍,梁长虹,曾辉,刘其顺,张忠林,张金娥,黄飚.多层螺旋CT在小儿复杂先天性心脏病诊断中的应用[J].中华放射学杂志,2004,38(7):726-731. 被引量:24
  • 2Writing Group Members,Lloyd-Jones D,Adams R J,et al.Heart disease and stroke statistics.2010 update:a report from the American Heart Association.Circulation,2010,121:e46-e215. 被引量:1
  • 3Ketelsen D,Thomas C,Werner M,et al.Dual-source computed tomography:estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography.Eur J Radiol,2010,73:274-279. 被引量:1
  • 4Herzog BA,Husmann L,Burkhard N,et al.Accuracy of lowdose computed tomography coronary angiography using prospective electrocardiogram-triggering:first clinical experience.Eur Heart J,2008,29:3037-3042. 被引量:1
  • 5Scheffel H,Alkadhi H,Leschka S,et al.Low-dose CT coronary angiography in the step-and-shoot mode:diagnostic performance.Heart,2008,94:1132-1137.44:265-268. 被引量:1
  • 6Pflederer T,Jakstat J,Marwan M,et at.Radiation exposure and image quality in staged tow-dose protocols for coronary dual-source CT angiography:a randomized comparison.Eur Radiol,2010,20:1197-1206. 被引量:1
  • 7Alkadhi H,Stolzmann P,Scheffel H,et al.Radiation dose of cardiac dual-source CT:the effect of tailoring the prolocol to patient-specific parameters.Eur J Radiol,2008,68:385-391. 被引量:1
  • 8Bastarrika G,Lee YS,Huda W,et al.CT of coronary artery disease.Radiology,2009,253:317-338. 被引量:1
  • 9Lu B,Mao SS,Zhuang N,et al.Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging.Invest Radio,2001,36:250-256. 被引量:1
  • 10Lell M,Marwan M,Schepis T,et al.Prospectively ECGtriggered high-pitch spiral acquisition for coronary CT angiogaphy using dual source CT:technique and initial experience.Eur Radiol,2009,19:2576-2583. 被引量:1