摘要
某山地风电场风机塔架基础因防水破坏,雨水渗入后导致基础内部出现空腔区,影响风机正常运行安全,通过采用环氧树脂灌浆加固处理,取得了较好的效果。
A cavity area was produced in the wind turbine tower foundation of a mountain wind farm due to the damage on rubber waterstop and rain leaking into the inside of the foundation, which affects the safe operation of the fan and was repaired by grouting of epoxy resin. The repair work obtains good results.
出处
《红水河》
2015年第1期22-24,共3页
Hongshui River
关键词
山地风电场
风机
塔架基础
mountain wind farm
wind turbine
tower foundation