期刊文献+

A rapid protein sample preparation method based on organic-aqueous microwave irradiation technique

A rapid protein sample preparation method based on organic-aqueous microwave irradiation technique
原文传递
导出
摘要 Fast and efficient sample preparation methods are a prerequisite for protein identification in bottom-up proteomics. Here, an innovative microwave irradiation sample preparation method was developed based on an optimized organic-aqueous solvent system for protein identification. Specifically, protein solutions containing high-concentration acetonitrile were subjected to 5 min microwave irradiation. After cooling down, trypsin was added and the digestion was performed with 30 s microwave irradiation, and the resulting peptides were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS). A shortened processing time of only 5.5 min is needed with this method(more than 12 h is necessary in the traditional overnight protein sample preparation). Moreover, due to the absence of urea and other chaotropic reagents, the digests can be readily identified by MALDI-TOF MS. When an assessment of this method was performed by digesting a model protein BSA, 69% ± 3% sequence coverage corresponding to 47 ± 3 peptides was obtained, which shows better protein identification than that from the standard overnight protein sample preparation method(51% ± 2% sequence coverage and 23 ± 1 peptides). Another model protein α-casein was used for the analysis of protein phosphorylation with the newly developed method that yielded 4 phosphopeptides with 8 phosphorylation sites, whereas 3 phosphopeptides with 2 phosphorylation sites were obtained from the traditional overnight approach. Moreover, the organic-aqueous microwave irradiation method provides effective digestion for proteins down to fmol. Fast and efficient sample preparation methods are a prerequisite for protein identification in bottom-up proteomics. Here, an innovative microwave irradiation sample preparation method was developed based on an optimized organic-aqueous solvent system for protein identification. Specifically, protein solutions containing high-concentration acetonitrile were subjected to 5 min microwave irradiation. After cooling down, trypsin was added and the digestion was performed with 30 s microwave irradiation, and the resulting peptides were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS). A shortened processing time of only 5.5 min is needed with this method(more than 12 h is necessary in the traditional overnight protein sample preparation). Moreover, due to the absence of urea and other chaotropic reagents, the digests can be readily identified by MALDI-TOF MS. When an assessment of this method was performed by digesting a model protein BSA, 69% ± 3% sequence coverage corresponding to 47 ± 3 peptides was obtained, which shows better protein identification than that from the standard overnight protein sample preparation method(51% ± 2% sequence coverage and 23 ± 1 peptides). Another model protein α-casein was used for the analysis of protein phosphorylation with the newly developed method that yielded 4 phosphopeptides with 8 phosphorylation sites, whereas 3 phosphopeptides with 2 phosphorylation sites were obtained from the traditional overnight approach. Moreover, the organic-aqueous microwave irradiation method provides effective digestion for proteins down to fmol.
出处 《Science China Chemistry》 SCIE EI CAS CSCD 2015年第3期526-531,共6页 中国科学(化学英文版)
基金 supported by the National Basic Research Program of China(2012CB910604,2013CB911202) the National Natural Science Foundation of China(21190043) the Innovation Method Fund of China(2012IM030900)
关键词 MALDI-TOF MS microwave organic-aqueous solvent protein identification DIGESTION 蛋白质组学 样品制备 制备方法 微波辐射技术 MALDI-TOF 水性 磷酸化位点 基质辅助激光解吸
  • 相关文献

参考文献28

  • 1Aebersold R, Mann M. Mass spectrometry-based proteomics. Nature, 2003, 422: 198-207. 被引量:1
  • 2Wang N, Xu MG, Wang P, Li L. Development of mass spectrometry-based shotgun method for proteome analysis of 500 to 5000 cancer cells. Anal Chem, 2010, 82: 2262-2271. 被引量:1
  • 3Dong MM, Wu MH, Wang FJ, Qin HQ, Han GH, Dong J, Wu RA, Ye ML, Liu Z, Zou HF. Coupling strong anion-exchange monolithic capillary with MALDI-TOF MS for sensitive detection of phosphopeptides in protein digest. Anal Chem, 2010, 82: 2907-2915. 被引量:1
  • 4Ma JF, Liu JX, Sun LL, Gao L, Liang Z, Zhang LH, Zhang YK. On-line integration of multiple sample pretreatment steps involving denaturation, reduction, and digestion with microflow reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry for high-throughput proteome profiling. Anal Chem, 2009, 81: 6534-6540. 被引量:1
  • 5Ma JF, Hou CY, Sun LL Tao DY, Zhang YY, Shan YC, Liang Z, Zhang LH, Yang L, Zhang YK. Coupling formic acid assisted solubilization and online immobilized pepsin digestion with strong cation exchange and microflow reversed-phase liquid chromatography with electrospray ionization tandem mass spectrometry for integral membrane proteome analysis. Anal Chem, 2010, 82: 9622-9625. 被引量:1
  • 6Klammer AA, MacCoss MJ. Effects of modified digestion schemes on the identification of proteins from complex mixtures. J Proteome Res, 2006, 5: 695-700. 被引量:1
  • 7Hervey IV WJ, Strader MB, Hurst GB. Comparison of digestion protocols for microgram quantities of enriched protein samples. J Proteome Res, 2007, 6: 3054-3061. 被引量:1
  • 8Chen WY, Chen YC. Acceleration of microwave-assisted enzymatic digestion reactions by magnetite beads. Anal Chem, 2007, 79: 2394-2401. 被引量:1
  • 9Lin S, Yao GP, Qi DW, Li Y, Deng CH, Yang PY, Zhang XM. Fast and efficient proteolysis by microwave-assisted protein digestion using trypsin-immobilized magnetic silica microspheres. Anal Chem, 2008, 80: 3655-3665. 被引量:1
  • 10Liu N, Wu HZ, Liu HX, Chen GN, Cai ZW. Microwave-assisted 18O-labeling of proteins catalyzed by formic acid. Anal Chem, 2010, 82: 9122-9126. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部