针对一些大工业用户力率调整电费过高的问题,文章选取典型案例通过现场校验结合系统运行情况进行分析,得出轻载系统功率因数过低是由于分布电容影响所致。并对实际案例利用MATLAB软件进行仿真计算,对比了2种不同负载运行下系统相关数据,验证了观点。
Since some large industrial users had the question on high price of force of electricity, this paper chooses typical case and analysised on the site calibration together with the system situation op- eration, then assumed the conclusion that the low power factor of the light load system is caused by the influence of distributed capacitance. By using the MATLAB software simulation and comparing the relevant system data of two different load operation, which verified the conclusion.