摘要 以类丁二炔化合物为有机染色材料,添加适量光引发剂,以聚酯片为基材,成功制备了一种高灵敏度辐射变色薄膜剂量计。经过5~1500 Gy的γ射线辐照后,薄膜灵敏层颜色由辐照前的淡粉色变为辐照后的蓝色,且随着辐照剂量的增加,颜色深度逐渐加深;分光光度计测试其吸收光谱,发现其主、次吸收峰分别在670 nm、613 nm附近;吸收峰处的吸光度响应与吸收剂量呈良好的线性关系;薄膜配方中添加适当比例的光引发剂,能够提高其响应灵敏度;吸光度响应随敏感层厚度与有机染色材料浓度的增加而增大;室温下避光贮存100 d ,吸收峰处的吸光度响应几乎不变,说明此种变色薄膜的稳定性良好。 A kind of radiochromic film dosimeter with high sensitivity had been devel‐oped by using polydiacetylene compounds as organic dye material ,using polyester chips as base material and adding an appropriate amount of photoinitiator .The color of the radiochromic film which was irradiated by γ‐ray changed from the light pink to blue . The color would be deepened with the increase of radiation dose;The master and second absorption peak located at 670 nm and 613 nm respectively by using spectrophotometer to test the absorption spectra;There was a good linear relationship between absorbance response at the absorption peaks and the absorbed dose;The response sensitivity would be improved by adding an appropriate amount of photoinitiator in the film formulation ;The absorption response would increase by the incensement in thickness of the film and the concentration of the organic dye material; The radiochromic films had been preserved for 100 days at room temperature ,avoiding from light .The result showed that the absorption response almost remained unchanged and the film’ s stability w as good .
出处 《同位素》 CAS 2014年第4期193-198,共6页 Journal of Isotopes
基金 国防基础科研项目(B2520133007)
关键词 类丁二炔化合物 辐射变色薄膜 Γ辐照 吸光度响应 polydiacetylene compound radiochromic film γ irradiation absorption response
  • 相关文献

参考文献8

  • 1徐雪春..辐射变色薄膜研究[D].四川大学,2006:
  • 2Butson M J, YuPKN, CheungT, etal. Radio chromic film for medical radiation dosimeter[J] Materials Science and Engineering, 2003, 41(3) 61-120. 被引量:1
  • 3唐掌雄,胡江潮,王艳乔,等.辐射变色薄膜剂量计[J].核技术,1985,1(017):56-57. 被引量:1
  • 4李华芝,肖振红,林敏,崔莹,陈克胜,叶宏生.辐射变色薄膜剂量计的研制[J].原子能科学技术,2008,42(3):253-257. 被引量:13
  • 5徐雪春,林理彬,蒋波,李军豪,邹萍.一种新型辐射变色膜的γ射线辐照研究[J].强激光与粒子束,2005,17(2):291-294. 被引量:15
  • 6Riel G K, Winters P, Patel G, et al. Selindica ting radiation alert dosemeter (SIRAD) [J]. Ra diation protection dosimetry, 2006, 120 ( 1 4) 259-262. 被引量:1
  • 7刘强,郑丹,蒋波,等.新型辐射变色薄膜剂量计研究[C]//第十届全国固体核径迹学术会议论文集.[s.n.],2009. 被引量:1
  • 8郭英杰,蒋波,何捷,等.聚丁二炔变色剂量功能性研究[c]//第七届中国功能材料及其应用学术会议论文集(第3分册).[s.n.],2010. 被引量:1

二级参考文献10

  • 1陈文琇,刘爱国.某些添加剂对PVG膜剂量计的效应[J].辐射研究与辐射工艺学报,1997,15(1):15-19. 被引量:2
  • 2Bishop W, Humpherys K, Randtke P. Poly (halostyrene) thin film dosimeters for high doses[J]. Review of Scientific Instruments, 1977,44 : 443-452. 被引量:1
  • 3McLaughlin W, Chen Y D, Soares C, et al. Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams[J]. Nuclear Instruments and Methods in Physical Research Section A, 1991, 302: 165-176. 被引量:1
  • 4Butson M J, Cheung T, Yu P K N. Spatial resolution of a stacked radiochromic film dosimeter[J]. Radiotherapy and Oncology, 2001, 61:211-213. 被引量:1
  • 5Nichiporov D, Kostjuchenko V, Puhl J, et al. Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams[J]. Applied Radiation and Isotopes, 1995, 46(12): 1355-1362. 被引量:1
  • 6Akhavan A, Sohrabpour M, Sharifzadeh M. Preparation of a new chemical radiochromic film dosimeter[J]. Radiation Physics and Chemistry, 2002, 63: 773-775. 被引量:1
  • 7Mikhailik M, Seropegina N, Melnikov M, et al. The kinetics and mechanism of photo-ageing of polyvinylbutyral [J]. European Polymer Journal, 1981, 17: 1011-1019. 被引量:1
  • 8HUMPHERYS K C. Radiochromic: A radiation monitoring system[J]. Radiat Phys Chem, 1977, 9:737-747. 被引量:1
  • 9张彦立,李承华,刘智绵,等.薄膜剂量计剂量学性能研究和应用[R].北京:国家技术监督局,1992. 被引量:1
  • 10LEVINE H. Temperature and humidity effects on the gamma-ray response and stability of plastic and dyed plastic dosimeters[J]. Radiat Phys Chem, 1979,14:551-574. 被引量:1

共引文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部