摘要 在聚乙烯醇缩丁醛(PVB)薄膜中添加LMG及有机卤代物(RX),研制成功PVG剂量计,并对其性能作了探讨[1]。结果表明,60Coγ射线辐照能引发体系中隐色的LMG氧化生成绿色的孔雀绿(MG+),生成数量与吸收剂量成正比。通过改变基体中LMG或RX的浓度,可以获得不同的线性剂量响应关系(即单位厚度的吸光度差△A/L,mm-1与剂量,kGy之间的关系),对合理控制PVG剂量膜的组成具有指导意义。此外,还初步探讨了该体系的辐射变色机理。 Dosifilm PVG was a new radiochromic film dosimeter composed of matrix material polyvinyl butyral (PVB), leuco malachite green (LMG) and additive halogenated organic compounds (RX), etc. The control of the dose range on PVG dosifilm was examined. The addition of halogenated compounds played an important role in the radiation reaction of LMG beyond the concentration of LMG.Bromide was more effective than chloride in this system, the oxidative species were X·and X2-. PVB with N-bromosuccinimide (NBS) induced the oxidation of LMG before irradiation. The reaction mechanism of PVG was discussed. Different linear ranges of radiation response on PVG dosifilm could be controlled by alternating the relative concentrations of halogenated compounds and LMG.
出处 《辐射研究与辐射工艺学报》 EI CAS CSCD 北大核心 1997年第1期15-19,共5页 Journal of Radiation Research and Radiation Processing
关键词 聚乙烯醇 缩丁醛 薄膜 辐射剂量 剂量计 Polyvinyl butyral, Leuco malachite green, Halogenated compounds,Radiation oxidation, Dosimeter
  • 相关文献

参考文献2

同被引文献15

  • 1谷渝秋,蔡达锋,郑志坚,温天舒,淳于书泰,陈家斌,周维民,焦春晔,陈豪.fs激光在靶背表面产生的质子束成丝(英文)[J].强激光与粒子束,2004,16(7):875-878. 被引量:4
  • 2周维民,谷渝秋,丁永坤,郑志坚,蔡达峰,淳于书泰,温天舒,陈豪,焦春晔,葛芳芳,王光昶,尤永禄玲,何颖玲.超短超强激光与Cu靶相互作用中质子背向发射的实验测量[J].强激光与粒子束,2004,16(11):1406-1408. 被引量:12
  • 3徐雪春,林理彬,蒋波,李军豪,邹萍.一种新型辐射变色膜的γ射线辐照研究[J].强激光与粒子束,2005,17(2):291-294. 被引量:15
  • 4Bishop W, Humpherys K, Randtke P. Poly (halostyrene) thin film dosimeters for high doses[J]. Review of Scientific Instruments, 1977,44 : 443-452. 被引量:1
  • 5McLaughlin W, Chen Y D, Soares C, et al. Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams[J]. Nuclear Instruments and Methods in Physical Research Section A, 1991, 302: 165-176. 被引量:1
  • 6Butson M J, Cheung T, Yu P K N. Spatial resolution of a stacked radiochromic film dosimeter[J]. Radiotherapy and Oncology, 2001, 61:211-213. 被引量:1
  • 7Nichiporov D, Kostjuchenko V, Puhl J, et al. Investigation of applicability of alanine and radiochromic detectors to dosimetry of proton clinical beams[J]. Applied Radiation and Isotopes, 1995, 46(12): 1355-1362. 被引量:1
  • 8Akhavan A, Sohrabpour M, Sharifzadeh M. Preparation of a new chemical radiochromic film dosimeter[J]. Radiation Physics and Chemistry, 2002, 63: 773-775. 被引量:1
  • 9Mikhailik M, Seropegina N, Melnikov M, et al. The kinetics and mechanism of photo-ageing of polyvinylbutyral [J]. European Polymer Journal, 1981, 17: 1011-1019. 被引量:1
  • 10Butson M J,Yu P K N,Cheung T,et al.Radiochromic film for medical radiation dosimetry[J].Materials Science and Engineering,2003,R41:61-120. 被引量:1