期刊文献+

零流电位法的性能及其能斯特响应的研究

Study on the Nernst Response and Performance of Zero Current Potentiometry
下载PDF
导出
摘要 探讨了零流电位法的检测原理,并利用一系列不同混合比例的铁氰化钾/亚铁氰化钾溶液考察了零流电位法的性能。实验结果表明:零流电位法具有能斯特响应的性能,同时表现出较高的准确性以及良好的精密度和重现性。 The measurement principle of zero current potentiometry was discussed and the performance of zero current potentiometry was investigated using a series of different ratio of ferrocyanide solution. The experimental results showed that zero current potentiometry agrees well with the Nernstian response. Besides, the new method exhibits higher accuracy, stability and repeatability.
出处 《广东化工》 CAS 2014年第19期77-78,84,共3页 Guangdong Chemical Industry
关键词 零流电位法 开路电位法 能斯特响应 zero current potentiometry open current potentiometry nernst response
  • 相关文献

参考文献21

  • 1Junxiang Guo,Yaqin Chai,Ruo Yuan,et al.Lead (Ⅱ) carbon paste electrode based on derivatized multi-walled carbon nanotubes:Application to lead content determination in environmental samples[J].Sens Actuators B Chem,2011,155:639-645. 被引量:1
  • 2Qian Li,Hong Li,Jin Zhang,et al.A novel pH potentiometric sensor based on electrochemically synthesized polybisphenol A films at an ITO electrode[J].Sens Actuators B Chem,2011,155:730-736. 被引量:1
  • 3Gehad G Mohamed,Tamer Awad Ali,El-Shahat M F,et al.Migahed.New Screen-Printed Ion-Selective Electrodes for Potentiometric Titration of Cetyltrimethylammonium Bromide in Different Civilic[J].Electroanalysis,2010,22(21):2587-2599. 被引量:1
  • 4RaA Sachez-Moreno,M Jess Gismera,M Teresa Sevilla,et al.Potentiometric Screen-Printed Bisensor for Simultaneous Determination of Chromium(Ⅲ) and Chromium(Ⅵ)[J].Electroanalysis,2011,23(1):287-294. 被引量:1
  • 5Abdelaziz Bouklouze,Mouloudi Elbuuzekraoui,Yahia Cherrah,et al.Potentiometric Sensor for Hydroxyzine Determination[J].Electroanalysis,2002,14:19-20. 被引量:1
  • 6Gamal Abdel-Hafiz MOSTAFA.PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid[J].AnnChim,2007,97:1247-1255. 被引量:1
  • 7Mehran Javanbakht,Solmaz Eynollahi Fard,Majid Abdouss,et al.A Biomimetic Potentiometric Sensor Using Molecularly Imprinted Polymer for the Cetirizine Assay in Tablets and Biological Fluids[J].Electroanalysis,2008,20(18):2023-2030. 被引量:1
  • 8Amr L Saber.Novel Potentiometric Sensors for Determination of Melatonin and Oxomemazine in Biological Samples and in Pharmaceutical Formulations[J].Electroanalysis,2010,22(24):2997-3002. 被引量:1
  • 9俞宝明,李幼荣.烟酸敏感场效应传感器的研制及应用[J].高等学校化学学报,1990,11(11):1281-1282. 被引量:2
  • 10程发良,莫金垣,戴晓云.聚吡咯修饰烟酸电位型生物传感器的制备与性能研究[J].化学通报,2000,63(1):22-25. 被引量:5

二级参考文献36

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部