离子选择电极法在电厂脱硝氨逃逸检测中的应用 被引量:4

Application of Ion Selective Electrode Method on Ammonia Escape Detection in Denitration of Power Plant
下载PDF
导出
摘要 脱硝氨逃逸浓度为一项重要的脱硝系统性能考核指标。结合DL/T 260—2012燃煤电厂烟气脱硝装置性能验收试验规范与工程实例介绍了测量燃煤电厂脱硝氨逃逸的靛酚蓝分光光度法和离子选择性电极法,着重对离子选择性电极法在电厂脱硝氨逃逸检测中的应用进行了说明。 Ammonia escape was an important performance evaluation index of denitrification. In this paper,combined with "Performance test code for denitration equipment of coal-fired flue gas" (DL/T 260--2012) and project exam- ples,the indophenol blue method and ion selective electrode method for ammonia escape detection in denitration of coal-fired plant were introduced, and application of the ion selective electrode method on ammonia escape in denitra- tion was described.
出处 《华北电力技术》 CAS 2014年第10期51-54,共4页 North China Electric Power
关键词 燃煤电厂 锅炉烟气 脱硝 氨逃逸 离子选择电极 coal fired power plant, flue gas of boiler, denitration, ammonia escape,ion selective electrode
  • 相关文献

参考文献4

  • 1孙克勤,钟秦编著..火电厂烟气脱硝技术及工程应用[M].北京:化学工业出版社,2007:185.
  • 2蒋文举主编..烟气脱硫脱硝技术手册[M].北京:化学工业出版社,2007:608.
  • 3DL/T260-2012,燃煤电厂烟气脱硝装置性能验收试验规范[S]. 被引量:6
  • 4GB/T14669-1993,空气质量氨的测定离子选择电极法[S]. 被引量:4