期刊文献+

饮用水中微量有害离子自动检测系统 被引量:2

Automatic Detection System for Microscale Harmful Ions in Drinking Water
下载PDF
导出
摘要 对饮用水中微量砷、氟离子自动检测系统设计进行了研究,主要介绍了系统的整体技术路线、液体自动进样、采集电路、控制软件以及信号处理。对于采集到的数据,系统提供了基于小波分析的信号去噪算法和峰面积计算方法,使得金属离子浓度的计算快速准确。整个测试系统操作简单、人机交互界面友好,支持检测参数设置,能够实现无人值守和远程无线控制,使饮用水中微量砷、氟离子的现场实时快速监测成为可能。 The design of automatic detection system for microscale arsenic and fluoride ions in drinking water has been studied. The overall technical route of the system,automatic liquid sampling,acquisition circuit,control software and signal processing are mainly introduced. For the data collected,the signal de-noising algorithm and peak area calculation method based on wavelet analysis are provided in the system,to make the calculation of metal ion concentration fast and accurate. The whole test system features simple operation,user-friendly man machine interface,and supporting detection parameter setup; in addition,the system can be unattended operated or implemented via remote wireless control,thus the real time rapid on-site monitoring for the microscale harmful arsenic and fluoride ions in drinking water becomes feasible.
作者 习海旭
出处 《自动化仪表》 CAS 北大核心 2014年第8期91-94,共4页 Process Automation Instrumentation
基金 江苏现代教育技术2011年度课题基金资助项目(编号:2011-R-18859) 常州云计算与智能信息处理重点实验室基金资助项目(编号:CM20123004)
关键词 信号处理 无线通信 电化学 数据采集 仪器仪表 小波变换 Signal processing Wireless communications Electrochemistry Data acquisition Instrumentation Wavelet transform
  • 相关文献

参考文献7

二级参考文献19

  • 1冯业铭,薛祚霖,程祖良.控制电位电解氮氧化物检测仪的研制[J].分析仪器,1994(4):19-23. 被引量:2
  • 2李素芬,刘钟阳,许东卫.控制电位型水中臭氧电化学传感器的试验研究[J].传感器与微系统,2006,25(1):58-60. 被引量:5
  • 3TURNER R B F,HARRISON D J,BALTES H P. A CMOS potentiostat for amperometric chemical sensors. IEEE J. Solid - State Circuits. 1987,22:473 - 478. 被引量:1
  • 4KAKEROW R G, KAPPERT H, SPIEGEL E, et al. Low power single chip CMOS potentiostat. The 8th International Conference on SolidState Sensors and Actuators, and Eurosensors IX, Stockholm Sweden, 1995. 被引量:1
  • 5BANDYOPADHYAY A, MULLIKEN G, CAUWENBERGHS G, et al. VLSI potentiostat array for distributed electrochemical neural recording. IEEE International Symposium on Circuits and Systems, Phoenix AZ,2002. 被引量:1
  • 6LIAO W Y, LEE Y G, HUANG C Y, et al. Telemetric electrochemical sensor. Biosensors and Bioelectronics. 2004,20( 3 ) :482 - 490. 被引量:1
  • 7BLANCO J R, FERRERO F J, CAMPO J C,et al. Design of a low-cost portable potentiostat for amperometric biosensors. IMTC 2006-Instrumentation and Measurement Technology Conference, Sorrento Italy, 2006. 被引量:1
  • 8AHMADI M M, JULLIEN G A. A very low power CMOS potentiostat for bioimplantable applications. Proceedings of the Fifth International Workshop on System-on-Chip for Real-Time Applications,2005. 被引量:1
  • 9MARTIN S M, GEBARA F H, STRONG T D, et al. A low-voltage, chemical sensor interface for systems-on-chip:The fully-differential potentiostat. IEEE International Symposium on Circuits and Systems, 2004. 被引量:1
  • 10戴逸松.电子系统噪声及低噪声设计方法[M].长春:吉林人民出版社,1985.. 被引量:2