期刊文献+

BOD微生物传感器检测方法的研究 被引量:3

Study on the Method of Detecting BOD Microbial Sensor
下载PDF
导出
摘要 采用固定化微生物分散悬浮的方法,进行了BOD微生物传感器及其检测方法的研究。该传感器响应大、测量范围广、稳定性好,测定BOD时,线性响应范围为0-500mg/L,线性相关系数达到0.99以上,且存在很好的重现性,响应时间在12min内。测定结果与BOD5标准方法具有良好的相关性,连续稳定地工作寿命在4个月以上。 The BOD biosensor used a double-layered mem-brane has lots of problem, as low response, narrow measuring range, and poor stability. For solving these problems, the method of BOD biosensor by suspending gel beads has been developed, which has high re-sponse, wide measuring range and fine stability. By using the sensor, a linear range was obtained up to 500mg/L BOD, its linear coefficient correlation was more than 0.99, and the response time was 12min. The sensor has a good repeatability. The output of the sensor was constant for over 4 months, and it has well interrelated to which determined by using conven-tional BOD5 analysis method.
出处 《上海环境科学》 CAS CSSCI CSCD 北大核心 2002年第7期405-407,共3页 Shanghai Environmental Sciences
基金 863计划资助项目 编号:863-818-Q-08
关键词 BOD 生物耗氧量 微生物传感器 检测方法 水质监测 BOD Microbial sensor Detection
  • 相关文献

参考文献4

  • 1杨汝德..现代工业微生物学[M],2001.
  • 2俞毓馨等主编..环境工程微生物检验手册[M].北京:中国环境科学出版社,1990:443.
  • 3杨洁彬等编著..乳酸菌 生物学基础及应用[M].北京:中国轻工业出版社,1996:256.
  • 4[4]American Public Health Association, American Water Works Association, Water Environment Federation.Standard Methods for the Examination of Water and Wastewater. Washington DC: American Public Health Association Publication Office, 1995,5~ 6. 被引量:1

同被引文献39

引证文献3

二级引证文献23