摘要
结合汽车空调压缩机的变工况性能 ,即汽车空调压缩机性能指标随转速和冷凝温度而变化的情况 ,根据汽车空调系统的冷凝器在不同设计工况下的设计结果 ,经过分析冷凝温度、冷却介质温差参数变化对冷凝器设计结果的影响 ,综合得出对满足汽车空调系统不同运行工况的冷凝器设计参数如冷凝温度、冷却介质温差等的合理选择 。
The performance of the compressor for automobile air conditioning under changing conditions is analyzed, and the designs of the automobile air conditioning condenser under different working conditions are discussed. By analyzing the effect of the changes in condenser temperature and increase of temperature of cooling medium on the design of the condenser, reasonable design parameters of the condenser are obtained. Finally the matching design of the condenser, compressor and whole system is achieved.
出处
《合肥工业大学学报(自然科学版)》
CAS
CSCD
2002年第1期139-142,共4页
Journal of Hefei University of Technology:Natural Science
关键词
汽车
空调
冷凝器
变工况
匹配设计
automobile air conditioning
condenser
changing conditions
matching design