期刊文献+

600MW超临界机组无外来辅助蒸汽热态启动方案探讨

Discussion on Hot Start Scheme of 600MW Supercritical Units without Auxiliary Steam
下载PDF
导出
摘要 针对超临界单台运行机组跳闸后重新启动存在依靠外来启动电源或外来辅助蒸汽作为启动汽源的问题,探索出一套无外来辅助蒸汽,不需要投入启动锅炉运行的机组快速热态启动方案。分析超临界机组实现无外来辅助蒸汽状态下的热态启动实践过程中存在的问题,根据实施方案提出了相应的控制措施,使得机组可快速实现热态启动。采用这种启动方式,可缩短机组热态启动时间约3.5 h,节约生产成本约15.4万元。 The supercritical unit relies on startup power or auxiliary steam in case of restart after tripping.This paper explores a fast startup scheme,in which auxiliary steam and startup boiler operation are all not necessary.The paper also analyzes problems in hot start of the units without auxiliary steam and proposes relevant control measures in accordance with implementation scheme so as to enable fast hot startup.By this startup mode,the time of hot startup can be reduced by 3.5 h,and production cost by 154 thousand Yuan.
作者 苏升文
出处 《广东电力》 2014年第4期36-40,共5页 Guangdong Electric Power
关键词 超临界机组 辅助蒸汽 热态启动 supercritical units auxiliary steam hot start
  • 相关文献

参考文献10

  • 1陈庚主编..单元机组集控运行[M].北京:中国电力出版社,2001:270.
  • 2楼波编..单元机组运行[M].北京:中国电力出版社,1999:97.
  • 3佛山恒益发电有限公司.集控运行规程[S].广州:佛山槛益发电有限公司,2012. 被引量:1
  • 4侯国威.新建火电厂无外来蒸汽而不设启动锅炉的启动研究[J].中国电力,2008,41(7):51-54. 被引量:6
  • 5大唐国际发电有限公司.大型火电机组经济运行及节能优化[M].北京:中国电力出版社,2012. 被引量:1
  • 6汪祖鑫编著..超临界压力600MW机组的启动和运行[M].北京:中国电力出版社,1996:234.
  • 7戴立洪..600MW超超临界机组启动特性研究[D].华北电力大学,2008:
  • 8常磊,杨冬,陈听宽.超临界直流锅炉启动系统和汽轮机旁路系统的研究[J].电站系统工程,2005,21(1):1-4. 被引量:6
  • 9上海锅炉厂.SG-1913/25.4-M983型锅炉使用说明书[Z].上海:上海锅炉厂,2010. 被引量:1
  • 10上海汽轮机厂.N600-242/566/566型600MW中间再热凝汽式汽轮机使用说明书[Z].上海:上海汽轮机厂,2009. 被引量:1