拉伸法测杨氏模量试验中,采用游标卡尺代替标尺进行测量读数,方法简单易行,望远镜内读数精度提高两位,并使最终杨氏模量测量结果的不确定度降低了一个数量级。对光杠杆测量微小变化量的实验研究,提高了实验分析验证的可行性,同时也拓宽了该研究领域。
For experiment measuring metals of Young's Modulus using stretched method, Using verni er caliper measurement instead of ruler,it increases the reading precision two-digit from telescope, and de- creases the Young's Modulus' uncertainty of one order of magnitude. This method is simple and easy. It im- proves the feasibility of experiment verification and widens the field to the research of light-lever measure- ment of minimal quantity.
出处
《数理医药学杂志》
2014年第2期215-218,共4页
Journal of Mathematical Medicine
关键词
杨氏模量
不确定度
Young' s modulus
uncertainty