危重患者容量失稳态治疗监测的研究进展 被引量:10

Research Progress of Monitoring of Treatment for Capacity Steady-state Loss in Critically Ill Patients
下载PDF
导出
摘要 对于ICU中的危重患者,尤其是血流动力学不稳定的患者,都面临容量治疗是否恰当的问题,因为患者的容量不足或者容量过负荷都会产生严重的后果,这个问题解决的好坏关系到重症患者治疗的成败,因此,评估患者的容量状态极其重要。目前用于ICU中的监测指标大致分为两部分,即血流动力学监测和组织灌注及氧代谢指标。近年来,这两部分指标由于诸多容量监测理论、监测技术和监测仪器的进步,使得一些静态压力指标、动态压力指标、容量指标及其监测仪器以及一些提示微循环灌注的指标被分别用来监测容量复苏的效能。 For critically ill patients in ICU with hemodynamic instability, the problem of capacity treat- ment appropriateness always exists,because the patient's lack of capacity or volume overload will have serious consequences. This problem is the key to success of the treatment for critically ill patients, therefore, the assessment of the patient's volume status is extremely important. Monitoring indicators currently used in the ICU are probably divided into two parts : hemodynamic monitoring/tissue perfusion and oxygen metabolism indicators. In recent years, due to the progress of the capacity monitoring theory, monitoring technology and tes- ting instruments, some static pressure indicators, dynamic pressure, volume indicators, monitoring instruments and some microcirculation perfusion indexes are used to monitor the effectiveness of volume resuscitation.
出处 《医学综述》 2014年第4期676-679,共4页 Medical Recapitulate
关键词 重症患者 容量治疗 监测指标 Critically ill patients Capacity treatment Monitoring indicators
  • 相关文献

参考文献27

  • 1Monnet X,Teboul JL.Volume responsiveness[J] .Curr Opin Crit Care,2007,13(5):549-553. 被引量:1
  • 2Marik PE,Baram M,Vahid B.Does central venous pressure predict fluid responsiveness?A systematic review of the literature and the tale of seven mares[J] .Chest,2008,134(1):172-178. 被引量:1
  • 3Boulain T,Achard JM,Teboul JL,et al.Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients[J] .Chest,2002,121(4):1245-1252. 被引量:1
  • 4Squara P,Waldmann C.Toward intelligent hemodynamic monitoring:a functional approach[J] .Cardiol Res Pract,2012,2012:630828. 被引量:1
  • 5Hofer CK,Muller SM,Furrer L,et al.Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting[J] .Chest,2005,128(2):848-854. 被引量:1
  • 6顾勤,刘宁,俞建峰.脉压变异对急性肺损伤机械通气患者血流动力学变化的临床价值[J].中国呼吸与危重监护杂志,2009,8(4):388-391. 被引量:4
  • 7Da Silva Ramos FJ,De Oliveira EM,Park M,et al.Heart-lung interactions with different ventilatory settings during acute lung injury and hypovolaemia:an experimental study[J] .Br J Anaesth,2011,106(3):394-402. 被引量:1
  • 8De Backer D,Taccone FS,Holsten R,et al.Influence of respiratory rate on stroke volume variation in mechanically ventilated patients[J] .Anesthesiology,2009,110(5):1092-1097. 被引量:1
  • 9Daudel F,Tuller D,Krahenbuhl S,et al.Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure:an expermental study[J] .Crit Care,2010,14(3):R122. 被引量:1
  • 10Renner J,Cavus E,Meybohm P,et al.Stroke volume variation during hemorrhage and after fluid loading:impact of different tidal volumes[J] .Acta Anaesthesiol Scand,2007,51(5):538-544. 被引量:1

二级参考文献50

共引文献160

同被引文献84

引证文献10

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部