摘要
针对伊朗某油田原油储罐消防系统设计,结合伊朗国家石油规范、美国防火协会标准和中国国家规范进行比较,分析储罐低倍数液下泡沫喷射灭火系统的适用条件和特点,并介绍液下喷射泡沫灭火系统的计算依据、系统设置和注意事项。
Based on the design of fire extinguishing system of crude oil storage tank in an oilfield of Iran and the comparison among Iranian Petroleum Standard, National Fire Protection Assiciation and National Standard of the People's Republic of China, the application condition and features of low expansion base injection foam extinguishing system were analyzed, and then, the calculation basis, setup and matters needing attention of base injection foam extinguishing system were also introduced.
出处
《工业用水与废水》
CAS
2014年第1期76-78,84,共4页
Industrial Water & Wastewater
关键词
原油储罐
泡沫灭火
液下喷射
crude oil storage tank
foam extinguishing
base injection