摘要 目的:评价脉搏容积波用于外周血管阻力监测的准确性及适用性。方法:采集30例健康志愿者不同接触压力下的桡动脉脉搏容积博(rPPG)和手指脉搏容积波(fPPG),分析其上升支斜率,并与超声多普勒所获取的桡动脉血流阻力指数进行相关分析。结果:桡动脉脉搏容积波上升支斜率与桡动脉血流阻力指数存在正相关(R=0.69,P<0.05),其相关性随着传感器接触压力的增加先增加后降低,而手指脉搏容积波上升支斜率与桡动脉血流阻力指数无相关关系。结论:脉搏容积波能反应监测部位的血管阻力,在监测外周血管阻力中具有潜在的应用价值。 Objective:To evaluate the efficacy and applicability of photoplethysmograph in peripheral vascular resistance monitor-ing. Methods:The radial arterial PPG waveform (rPPG) of different contacted pressure and finger’s PPG waveform (fPPG) were col-lected in the thirty volunteers. The slope of systolic upstroke in fPPG waveform and rPPG waveform of different contacted pressure were calculated, and analyzed the correlation with resistance index (RI) of radial artery collected by ultrasound Doppler. Results:the slope of systolic upstroke in rPPG waveform had a significant positive linear correlation with RI (R=0.69, P&lt;0.05), the correlation co-efficient was increased firstly and then decreased with the contacted pressure increasing. There were no correlations between slope of systolic upstroke from fPPG waveform and RI of radial artery. Conclusion:the PPG waveform presented association with vascular re-sistance of monitoring site. It promises to be important act on peripheral vascular resistance monitoring.
出处 《激光杂志》 CAS CSCD 北大核心 2014年第2期76-78,共3页 Laser Journal
基金 国家自然科学基金资助课题(基金号:0200040679) 国家临床重点专科建设项目经费资助 重庆市医学重点学科建设经费资助
关键词 脉搏容积波 桡动脉 手指 外周血管阻力 接触压力 photoplethysmograph radial artery finger peripheral vascular resistance contacted pressure
  • 相关文献

参考文献17

  • 1Vasapollo B,Novelli GP,Gagliardi G. Medical treatment of early-onset mild gestational hypertension reduces total peripheral vascular resistance and influences maternal and fetal complications[J].{H}Ultrasound in Obstetrics & Gynecology,2012,(03):325-331. 被引量:1
  • 2Andrew R,Phillip AS,Devin MC. Utility of the Photoplethys-mogram in Circulatory Monitoring[J].{H}ANESTHESIOLOGY,2008.950-958. 被引量:1
  • 3Meir N,Amikam P,Zehava G. Automatic noninvasive mea-surement of systolic blood pressure using photoplethysmography[J].{H}BioMedical Engineering OnLine,2009.28-36. 被引量:1
  • 4Glauco AW,Eliezer S,Anderson RG. Pulse oximetry wave variation as a noninvasive tool to assess volume status in cardiac surgery[J].CLINICS,2009,(04):337-343. 被引量:1
  • 5Phillips JP,Hickey M,Kyriacou PA. Evaluation of electrical and optical plethysmography sensors for noninvasive monitoring of he-moglobin concentration[J].Sensors(Basel),2012,(02):1816-1826. 被引量:1
  • 6Keisuke M,Kazuo AO,Naoto K. Fundamental Study of Reflec-tion Pulse Oximetry[J].{H}OPTICAL REVIEW,2003,(05):482-487. 被引量:1
  • 7Mou L,Gong Q,Wei W. The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources[J].{H}Journal of Clinical Monitoring and Computing,2013,(03):365-370. 被引量:1
  • 8崔波,高博,龚敏.基于红外反射光容积脉搏波的血管阻力研究[J].光散射学报,2011,23(4):406-410. 被引量:6
  • 9高博,魏蔚,龚敏,王丽.利用近红外光谱检测多层组织血氧饱和度的研究[J].光谱学与光谱分析,2009,29(11):2922-2925. 被引量:9
  • 10H Chan G,Middleton P,Lovell N. Extraction of photople-thysmographic waveform variability by lowpass filtering[J].Engi-neering in Medicine and Biology Society,2005.5568-5571. 被引量:1

二级参考文献27

  • 1刘晓石.概率论与数理统计[M].北京:科学出版社,2005.85-89. 被引量:8
  • 2Martínez-Simón A, Monedero P, Cacho-Asenjo E.Erroneous measurement of haemodynamic parameters by PiCCO(TM) monitor in a critically ill patient with renal replacement therapy: a case report[J].Crit Care,2006,10(2):410. 被引量:1
  • 3Oshima K, Kunimoto F, Hinohara H.The evaluation of hemodynamics in post thoracic esophagectomy patients[J].Hepatogastroenterology,2008,55(85):1338-1341. 被引量:1
  • 4Martin G S, Eaton S, Mealer M, et al.Extravascular lung water in patients with severe sepsis: a prospective cohort study[J].Crit Care,2005,9(2):R74-82. 被引量:1
  • 5Szakmany T, Heigl P, Molnar Z.Correlation between extravascular lung water and oxygenation in ALI/ARDS patients in septic shock: possible role in the development of atelectasis[J].Anaesth Intensive Care,2004,32(2):196-201. 被引量:1
  • 6Sato Y, Motoyama S, Maruyama K, et al.Extravascular lung water measured using single transpulmonary thermodilution reflects perioperative pulmonary edema induced by esophagectomy[J].Eur Surg Res,2007,39(1):7-13. 被引量:1
  • 7Naidu B V, Dronavalli V B, Rajesh P B.Measuring lung water following major lung resection[J].Interact Cardiovasc Thorac Surg,2009,8(5):503-506. 被引量:1
  • 8Wiener R S, Welch H G.Trends in the use of the pulmonary artery catheter in the United States, 1993-2004[J].JAMA,2007,298(4):423-429. 被引量:1
  • 9Phillips C R, Chesnutt M S, Smith S M.Extravascular lung water in sepsis-associated acute respiratory distress syndrome: indexing with predicted body weight improves correlation with severity of illness and survival[J].Crit Care Med,2008,36(1):69-73. 被引量:1
  • 10Kuzkov V V, Kirov M Y, Sovershaev M A, et al.Extravascular lung water determined with single transpulmonary thermodilution correlates with the severity of sepsis-induced acute lung injury[J].Crit Care Med,2006,34(6):1647-1653. 被引量:1

共引文献69

同被引文献5

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部