期刊文献+

LISS钢板内固定治疗复杂胫骨骨折的临床疗效分析 被引量:17

原文传递
导出
摘要 目的探讨应用微创固定系统(LISS)治疗胫骨复杂骨折的临床疗效。方法应用LISS内固定系统通过间接复位、经皮插入LISS钢板治疗胫骨复杂骨折23例。结果患者获得随访5-25个月,骨折全部愈合,平均愈合时间为(6.0±2.1)个月。患肢功能情况按照Johner-Wruhs评价标准:优16例,良4例,可3例,优良率87.O%。结论LISS钢板内固定治疗胫骨复杂骨折是一种有效微创内固定治疗方案,具有创伤小、骨折愈合率高、并发症少的优点。
出处 《中国骨与关节损伤杂志》 2014年第1期86-87,共2页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献8

  • 1Johner R,Wruhs O. Classification of tibal shaft fracture and correlation with results after rigid internal fixation [J]. Clin Orthop, 1983,178:7-25. 被引量:1
  • 2何锦泉,庞贵根,胡永成.微创经皮接骨板技术在下肢骨折中的应用[J].中国骨与关节损伤杂志,2007,22(11):966-968. 被引量:66
  • 3James P Stannard,Christopher G Finkemeier,Jackson Lee,et al. Utilization of the less-invasive stabilization system internal fixator for open fractures of the proximal tibia:a multi-center evaluation[J]. Indian J Orthop, 2008,42(4) : 426-430. 被引量:1
  • 4Kregor PJ,Stannard JA,Zlowodzki M,et al. Treatment of distal femur fractures using the less invasive stabilization system:surgical experience and earlyclinieal results in 103 fractures [J]. J Orthop Trauma ,2004,18(8) :509-520. 被引量:1
  • 5Stannard JP,Wilson TC,Volgas DA,et al. The less invasive stabilization system in the treatment of complex fractures of the tibial plateau :short-termresults [J]. J Orthop Tranma,2004,18(8): 552-558. 被引量:1
  • 6祁小松,刘双会,胡向军,安志军.LISS治疗膝周骨折致医源性并发症分析及预防[J].中国骨与关节损伤杂志,2011,26(2):146-147. 被引量:4
  • 7Wong EW,Lee EW. Percutaneous plating of lower limb long bone fractures[J]. Injury ,2006,37(6) :543-553. 被引量:1
  • 8Deangelis JP,Deangelis NA,Anderson IL Anatomy of the superficial peroneal nerve in relation to fixation of tibia fractures with the less invasive stabilization system[J]. J Orthop Trauma,2004,18(8):536- 539. 被引量:1

二级参考文献27

  • 1钟贵彬,侯春林,张伟,徐镇.微创内固定系统治疗骨折失误原因分析及对策(附三例报告)[J].中国骨与关节损伤杂志,2007,22(2):164-165. 被引量:18
  • 2Stoffel K,Dieter U,StachowiakG,et al.Biomechanical testing of the LCP--how can stability inlocked internal fixators be controlled?Injury,2003,34 (2):11-19. 被引量:1
  • 3Zehnder S, Bledsoe JG,Puryear A.The effects of screw orientation in severely osteoporotic bone: acomparison with locked plating.Clin Biomeeh (Bristol Avon), 2009,24(7):589. 被引量:1
  • 4Fitzpatrick DC,Doornink J,Madey SM,et al.Relativestability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis.Clin Biomech (Bristnl,Avon), 2009,24(2):203. 被引量:1
  • 5Bottlang M,Doornink J,Byrd GD,et al.Anonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.J Bone Joint Surg (Am) ,2009, 91(3):620. 被引量:1
  • 6Wagner M.General principles for the clinical use of the LCP.Injury,2003,34 (2):31 被引量:1
  • 7Krettek C.Forword:concepts of minimally invasive plate osteosynthesis.Injury,1997,28:1 被引量:1
  • 8Farok O,Krettek C,Miclau T,et al.Minimally invasive plate osteosynthesis and vascularity:preliminary results of a cadaver injection study.Injury,1997,28 (1):7 被引量:1
  • 9Karl Stoffel,Ulrich Dieter,Gwidon Stachowiak,et al.Biomechanical testing of the LCP-How can stability in locked internal fixators be controlled.Injury,2003,34:11 被引量:1
  • 10Fankhauser C,Frenk A,Marti A.A comparative biomechanical evaluation of three systems for the internal fixation of distal fractures of the femur.Orthopaedic Research Society,1999,24 (1):498 被引量:1