期刊文献+

Microscopic degradation mechanism of polyimide film caused by surface discharge under bipolar continuous square impulse voltage 被引量:1

Microscopic degradation mechanism of polyimide film caused by surface discharge under bipolar continuous square impulse voltage
下载PDF
导出
摘要 Polyimide (PI) film is an important type of insulating material used in inverter-fed motors. Partial discharge (PD) under a sequence of high-frequency square impulses is one of the key factors that lead to premature failures in insulation systems of inverter-fed motors. In order to explore the damage mechanism of PI film caused by discharge, an aging system of surface discharge under bipolar continuous square impulse voltage (BCSIV) is designed based on the ASTM 2275 01 standard and the electrical aging tests of PI film samples are performed above the partial discharge inception voltage (PDIV). The chemical bonds of PI polymer chains are analyzed through Fourier transform infrared spectroscopy (FTIR) and the dielectric properties of unaged and aged PI samples are investigated by LCR testers HIOKI 3532-50. Finally, the micro-morphology and micro-structure changes of PI film samples are observed through scanning electron microscopy (SEM). The results show that the physical and chemical effects of discharge cut off the chemical bonds of PI polymer chains. The fractures of ether bond (C-O-C) and imide ring (C-N-C) on the backbone of a PI polymer chain leads to the decrease of molecular weight, which results in the degradation of PI polymers and the generation of new chemical groups and materials, like carboxylic acid, ketone, aldehydes, etc. The variation of microscopic structure of PI polymers can change the orientation ability of polarizable units when the samples are under an AC electric field, which would cause the dielectric constant e to increase and dielectric loss tan ~ to decrease. The SEM images show that the degradation path of PI film is initiated from the surface and then gradually extends to the interior with continuous aging. The injection charge could result in the PI macromolecular chain degradation and increase the trap density in the PI oolvmer bulk. Polyimide (PI) film is an important type of insulating material used in inverter-fed motors. Partial discharge (PD) under a sequence of high-frequency square impulses is one of the key factors that lead to premature failures in insulation systems of inverter-fed motors. In order to explore the damage mechanism of PI film caused by discharge, an aging system of surface discharge under bipolar continuous square impulse voltage (BCSIV) is designed based on the ASTM 2275 01 standard and the electrical aging tests of PI film samples are performed above the partial discharge inception voltage (PDIV). The chemical bonds of PI polymer chains are analyzed through Fourier transform infrared spectroscopy (FTIR) and the dielectric properties of unaged and aged PI samples are investigated by LCR testers HIOKI 3532-50. Finally, the micro-morphology and micro-structure changes of PI film samples are observed through scanning electron microscopy (SEM). The results show that the physical and chemical effects of discharge cut off the chemical bonds of PI polymer chains. The fractures of ether bond (C-O-C) and imide ring (C-N-C) on the backbone of a PI polymer chain leads to the decrease of molecular weight, which results in the degradation of PI polymers and the generation of new chemical groups and materials, like carboxylic acid, ketone, aldehydes, etc. The variation of microscopic structure of PI polymers can change the orientation ability of polarizable units when the samples are under an AC electric field, which would cause the dielectric constant e to increase and dielectric loss tan ~ to decrease. The SEM images show that the degradation path of PI film is initiated from the surface and then gradually extends to the interior with continuous aging. The injection charge could result in the PI macromolecular chain degradation and increase the trap density in the PI oolvmer bulk.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期491-498,共8页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China (Grant Nos.U1234202,U1134205,51177136,and 51107104)
关键词 surface discharge polyimide film micro-morphology and micro-structure degradation process surface discharge, polyimide film, micro-morphology and micro-structure, degradation process
  • 相关文献

参考文献32

  • 1Gao Q, Asher G M, Sumner M and Makys P 2007 IEEE Trans. Ind. Appl. 43 1001. 被引量:1
  • 2Ahmed T, Nishida K and Nakaoka M 2006 IEEE Trans. Ind. Appl. 42 934. 被引量:1
  • 3Kau:old M, Aninger H, Berth M, Speck J and Eberhardt M 2000 IEEE Trans. Ind. Electron. 47 396. 被引量:1
  • 4Melfi M, Sung A M J, Bell S and Sldbinski G L 19981EEE Trans. Ind. Appl. 34 766. 被引量:1
  • 5Yin W J 1997 IEEE Trans. Electr. lnsul. Mag. 13 18. 被引量:1
  • 6Hayakawa N and Okubo H 2005 IEEE Electr. Insul. Mag. 21 5. 被引量:1
  • 7Hudon C, Amyot N, Lebcy T, Castelan P and Kandev N 2000 IEEE Trans. Dielectr Electr. Insul. 7 783. 被引量:1
  • 8Coletti G, Guastavino F and Torello E 2002 Conference Record of the IEEE International Symposium on Electrical Insulation, April 7-10, 2002, Boston, USA, p. 36. 被引量:1
  • 9Morshuis P H F 2005 IEEE Trans. Dielec: Electr Insul. 12 905. 被引量:1
  • 10Liu F D, Yang B T, Tu D M and Liu Y N 1992Acta Phys. Sin. 41 333 (in Chinese). 被引量:1

同被引文献13

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部