期刊文献+

有源电力滤波器电容电压启动控制研究 被引量:7

Research on Start Control of Capacitor Voltage in Active Power Filter
下载PDF
导出
摘要 针对有源电力滤波器(APF)投入电网启动时的冲击电流、电压问题,在已有的直流侧电容电压控制方法基础上,提出一种改进型多比例积分(PI)控制器的控制策略进行软启动,使电容电压从零到电容电压期望值的上升率、超调量得到有效控制。在Matlab/Simulink中进行仿真验证,并在60 kVA实验样机中进行实验,结果证明了该方法的正确性和可行性。 For the issue of over current and over voltage which occurs while the active power filter (APF) is started into the grid,an improved multi proportional integral(PI) control strategy in the method for soft-start is presented based on the control method of the existing DC capacitor voltage, making capacitor voltage be controlled from zero to capac- itor voltage expectation effectively in rate of its rise and the overshoot.The results by Matlab/Simulink and a 60 kVA experiment prototype demonstrate the correctness and the validity of the theory.
机构地区 兰州交通大学
出处 《电力电子技术》 CSCD 北大核心 2014年第2期46-48,共3页 Power Electronics
基金 甘肃省自然科学基金(1308RJYA044)~~
关键词 有源电力滤波器 电压冲击 电流冲击 软启动 active power filter over voltage over current soft-start
  • 相关文献

参考文献6

二级参考文献5

共引文献50

同被引文献47

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部