摘要
讨论了并联型有源电力滤波器直流侧电压的计算和直流侧电容容量的选择问题 ,提出了APF投入电网的方法并将模糊理论运用于直流侧的电压控制 ,并在实际装置上进行了验证。
This paper discusses the calculation of DC voltage and selection of capacitor according to research on parallel active power filter.A new method for APF launching into power system is presented and a fuzzy theory for voltage stability control is given out .In the end,the test in practice is shown.
出处
《电工技术杂志》
2002年第10期27-29,共3页
Electrotechnical Journal