湿法脱硫系统吸收塔除雾器改造分析及应用 被引量:2

Analysis and application of absorber mist eliminator renovation of the WFGD system
下载PDF
导出
摘要 为了提高除雾效果,改善GGH堵塞情况,将原来两层平板式除雾器改造为一级管式加两级屋顶式除雾器,并详细介绍了除雾器及吸收塔的改造措施、改造工期、改造费用和改造效果,本次改造有效减少了吸收塔出口的石膏液滴含量,保证了取消旁路后脱硫系统的正常稳定运行,经济效益和社会效益显著。 In order to improve the effect of mist eliminator and avoid GGH blockage, upgraded project which change the 2-layer flat mist eliminator into the l-layer pipe-type plus 2-layer roof mist eliminator was proposed. The measures, time, expenses and effect of the mist eliminator and absorber renovation were particularly introduced. The liquid car- ryover rate in absorber outlet was reduced after the renovation. The steady operation of FGD system without bypass was ensured. The environmental and social benefits were obvious.
作者 沈海涛
出处 《能源工程》 2013年第6期61-63,共3页 Energy Engineering
关键词 除雾器 湿法脱硫 堵塞 改造 mist eliminator FGD blockage renovation