期刊文献+

全身成像三维量化评估二尖瓣反流与实时三维超声心动图的对比研究 被引量:2

Evaluation of mitral regurgitation by general imaging 3-dimensional quantification comparison with real-time 3-dimensional echocardiography
下载PDF
导出
摘要 目的探讨全身成像三维量化(GI3DQ)法测量二尖瓣反流束体积的可行性和准确性。方法 93例二尖瓣反流(MR)患者:偏心性MR组52例,中心性MR组41例。GI3DQ法直接测量MR体积,以实时三维超声心动图(RT3DE)计算的MR体积作为参考标准。结果在偏心性MR组,两种方法相关性:r=0.91;一致性分析:GI3DQ法较RT3DE法平均低估MR体积约10.6 ml;在中心性MR组,两种方法相关性:r=0.96;一致性分析差异无统计学意义。结论在偏心性MR组,GI3DQ法评估MR体积存在明显低估;在中心性MR组,GI3DQ法与RT3DE法未见明显差异。 Objective To evaluate feasibility and accuracy of mitral regurgitant volume (MRvol) by quantification of mitral regurgitation (MR) jet volume using general imaging 3-dimensional quantification (GI3DQ). Methods Ninety-three patients with MR were divided into central MR group (n=41) and eccentric MR group (n=52). Mitral regurgitation jet volume was measured using GI3DQ. The MRvol calculated by real-time 3-dimensional echocardiography (RT3DE) was used as reference standard. Results In eccentric MR group, MRvol measured by GI3DQ method with a lower underestimation (mean difference = -10.6 ml) showed good correlation with MRvol measured by RT3DE(r = 0.91 ). In central MR group, the correlation of MRvol measured by GI3DQ method and by RT3DE method was better (r = 0.96 ), but had no significant difference. Conclusion Quantification of central MRvol with GI3DQ was as accurate as RT3DE,but GI3DQ method underestimated eccentric MRvol.
出处 《临床超声医学杂志》 2013年第11期741-744,共4页 Journal of Clinical Ultrasound in Medicine
基金 国家自然科学基金面上项目(81071161)
关键词 超声心动描记术 实时 全身成像三维量化 二尖瓣反流 Echocardiography, real-time General imaging 3-dimensional quantification Mitral regurgitation
  • 相关文献

参考文献10

  • 1Bursi F, Enriquez-Sarano M, Nkomo VT, et al. Heart failure and death after myocardial infarction in the community: the emerging role of mitral regurgitation. Circulation, 2005,111 ( 3 ) : 295-301. 被引量:1
  • 2Rosenhek R, Rader F, Klaar U, et al. Outcome of watchfid waiting in asymptomatic severe mitral regurgitation. Circulation,2006, 113 ( 18 ): 2238-2244. 被引量:1
  • 3Laneellotti P, Moura L, Pierard LA, ct al. European association of echocardiography recommendations for the assessment of valvular regurgitation, part 2: mitral and tricuspid regurgitation (native disease ). Eur J Echocardiogr , 2010, 11 (4) : 307-332. 被引量:1
  • 4Marsan NA, Westenberg J J, Ypenburg C, et al. Quantification of functional mitral regurgitation by real time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance. JACC Cardiovasc Imaging , 2009,2( 11 ): 1245-1452. 被引量:1
  • 5Marsan NA, Westenberg J J, Roes SD, et al. Three-dimensional echocardiography for the preoperative assessment of patients with left ventricular aneurysm. Ann Thorac Surg , 2011,91 ( 1 ) : 113-121. 被引量:1
  • 6de Agust i n JA, Marcos-Alberca P, Femandez-Golfin C, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr,2012,25(8) : 815-823. 被引量:1
  • 7Grayburn PA, Weissmml NJ, Zamorano JL. Quantitation of mitral regurgitation. Circulation, 2012,126 ( 16 ) : 2005-2017. 被引量:1
  • 8Chao K, Moises VA, Shandas R, et al. Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping. Circulation, 1992,85( 1 ):333-341. 被引量:1
  • 9Shiota T, Sinclair B, Ishii M, et al. Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: an in vitro quantitative study.J Am Coil Cardiol, 1996,27 (6) : 1511-1518. 被引量:1
  • 10Sugeng L, Weinert L, Lang RM. Real-time 3-dimensional color Doppler flow of mitral and tricuspid regurgitation: feasibility and initial quantitative compm-ison with 2-dimensional methods. J Am Soc Echocardiogr, 2007,20( 9 ) : 1050-1057. 被引量:1

同被引文献5

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部