研究了超声波雾化去溶进样电感耦合等离子体质谱法(ICP-MS)测定地质样品中超痕量稀土元素含量的方法,稀土元素的检出限低达0.3~4pg/ml,能检测稀土总量为ng/g级的固体样品中的15个稀土分量。
A method for determining ultra-trace rare earth elements by using ICP-MS with ultrasonic nebulization has been improved and peformances of ultrasonic nebulization with desolvation have been presented. The detection limits of method are from 0.3 to 4pg/ml which are 20—100 times lower than that obtained by pneumatic nebulizer. Rare earth elemonts at ppb levols in ultrabasic rocks can be analyzed.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1991年第6期625-630,共6页
Chinese Journal of Analytical Chemistry
关键词
超痕量
稀土元素
测定
ICP-MS
矿石
Inductively coupled plasma-mass spectrometry, Ultrasonic nebulization, Rare earth elements, Ultrabasic recks