摘要
目的:探讨经前处理用比色法测定医院污水中总余氯的方法。方法:样品经沉淀处理进行比色分析。结果:方法检出限为0.02mg/L,相对标准偏差在1.36%~5.86%之间,加标回收率在95.0%~103%。结论:本法简便,快速,可用于医院污水中余氯的测定。
Objective: To discuss the measure of colorimetric determination of total residual chlorine in the hospital sewage through pretreatment. Methods: The samples that were precipitated and treated were analyzed colorimetrically. Results: The detection limit of the method was 0.02mg/L. The relative standard deviation was between 1.36%-5.86%.The spiked recoveries were between 95.0%~103.0%. Conclusion: The method is simple and fast that can be used for the determination oftotal residual chlorine in the hospital sewage.
出处
《上海医药》
CAS
2013年第20期55-57,共3页
Shanghai Medical & Pharmaceutical Journal
关键词
医院污水
余氯
比色法
测定方法
hospital sewage
total chlorine
eolorimetry
method for determination