为探讨建筑凹槽内空调室外机运行时的温度场和气流场,以某住宅建筑为例,利用CFD模拟的方法,分析了不同的室外机安装条件对空调运行产生的影响,得出了最佳的室外机安装条件。
To analyze the temperature field and the flow field of outdoor units which are located at re-entrant of a building, a certain building is taken as an example to analyze the impact of outdoor units under different installation conditions and the best installation conditions are proposed.