摘要 The most important aim of nanotechnology development is to construct atomic-scale devices, and those atomic-scale devices are required to use some measurements that have ability to control and build in the range of these dimensions. A method based on super- heterodyne interferometers can be used to access the measurements in nano-scale. One of the most important limitations to increase the resolution of the displacement measurement is nonlinearity error. According to the base and measurement signals received by optical section of super-heterodyne interferometer, it is necessary for circuits to reconstruct and detect corresponding phase with target displacement. In this paper, we designed, simulated, and implemented the circuits required for electronic part of interferometer by complementary metal-oxide-semicon- ductor (CMOS) 0.5 ~tm technology. These circuits included cascade low-noise amplifiers (LNA) with 19.1 dB gain and 2.5dB noise figure (NF) at 500MHz frequency, band-pass filters with 500MHz central fre- quency and 400 kHz bandwidth, double-balanced mixers with 233/0.6pm ratio for metal-oxide-semiconductor field-effect transistors (MOSFETs), and low-pass filters with 300 kHz cutoff frequency. The experimental results show that the amplifiers have 19.41 dB gain and 2.7 dB noise factor, mixers have the ratio of radio frequency to local oscillator (RF/LO) range between 80 and 2500 MHz with intermediate frequency (IF) range between DC to 1000 MHz, and the digital phase measurement circuit based on the time-to-digital converter (TDC) has a nanosecond resolution. The most important aim of nanotechnology development is to construct atomic-scale devices, and those atomic-scale devices are required to use some measurements that have ability to control and build in the range of these dimensions. A method based on super- heterodyne interferometers can be used to access the measurements in nano-scale. One of the most important limitations to increase the resolution of the displacement measurement is nonlinearity error. According to the base and measurement signals received by optical section of super-heterodyne interferometer, it is necessary for circuits to reconstruct and detect corresponding phase with target displacement. In this paper, we designed, simulated, and implemented the circuits required for electronic part of interferometer by complementary metal-oxide-semicon- ductor (CMOS) 0.5 ~tm technology. These circuits included cascade low-noise amplifiers (LNA) with 19.1 dB gain and 2.5dB noise figure (NF) at 500MHz frequency, band-pass filters with 500MHz central fre- quency and 400 kHz bandwidth, double-balanced mixers with 233/0.6pm ratio for metal-oxide-semiconductor field-effect transistors (MOSFETs), and low-pass filters with 300 kHz cutoff frequency. The experimental results show that the amplifiers have 19.41 dB gain and 2.7 dB noise factor, mixers have the ratio of radio frequency to local oscillator (RF/LO) range between 80 and 2500 MHz with intermediate frequency (IF) range between DC to 1000 MHz, and the digital phase measurement circuit based on the time-to-digital converter (TDC) has a nanosecond resolution.
出处 《Frontiers of Optoelectronics》 EI CSCD 2013年第3期318-326,共9页 光电子前沿(英文版)
关键词 super-heterodyne interferometer nano-metrology low-noise amplifier (LNA) double-balancedmixer phase measurement super-heterodyne interferometer, nano-metrology, low-noise amplifier (LNA), double-balancedmixer, phase measurement
  • 相关文献

参考文献26

  • 1Schatt,enburg M L, Smith H I. The critical role of metrology in nanote.chnology. SPIE Proceedings, 2001, 4608:116-124. 被引量:1
  • 2Burggraaf P. Optical lithography to 2000 and beyond. Solid State Technology, 1999, 42(2): 31-41. 被引量:1
  • 3Lawall J, Kessler E. Michelson interferometry with 10 pm accuracy. Review of Scientific Instruments, 2000, 71 (7): 26695676. 被引量:1
  • 4Olyaee S, Nejad M. Nonlinearity and frequency-path modelling of three-longitudinal-mode nanometric displacement measurement system. IET Optoelectronies, 2007, 1 (5): 211-220. 被引量:1
  • 5Yokoyama T, Araki T, Yokoyama S, Suzuki N. A subnanometer heterodyne interferometrie system with improved phase sensitivity using a three-longitudinal-mode He Ne laser. Measurement Science and Te.chnology, 2001, 12(2): 157-162. 被引量:1
  • 6Olyaee S, Hamedi S. A low-nonlinearity laser heterodyne interferometer with quadrupled resolution in the displacement measurement. Arabian Journal for Science and Engineering, 2011, 36(2): 279-286. 被引量:1
  • 7Guo J H, Zhang Y, Shen S. Compensation of nonlinearity in a new optical[ heterodyne interferometer with doubled measurement resolution. Optics Communications, 2000, 184(1-4): 49-55. 被引量:1
  • 8Olyaee S, Nejad S M. Error analysis, design and modeling of an improved heterodyne nano-displacement interferometer. Iranian Journal of Electrical and Electronic Engineering, 2007, 3(3-4): 53-63. 被引量:1
  • 9Quenelle R C. Nonlinearity in interferometric measurements. Hewlett-Parkard Journal, 1983, 34(10): 3-13. 被引量:1
  • 10Sutton C M. Non-linearity in the length measurement using hetrodyne laser Michelson interferometery. Journal of Physics E, Scientific Instruments, 1987, 20(10): 1290-1292. 被引量:1

相关作者